Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
One of the crucial detector systems of the Pierre Auger Observatory is the fluorescence detector composed of 27 large-aperture wide-angle Schmidt telescopes. In the past, these telescopes were absolutely calibrated by illuminating the whole aperture with a uniform large-diameter light source. This absolute calibration was performed roughly once every three years, while a relative calibration was performed on a nightly basis. In this contribution, a new technique for an absolute end-to-end calibration of the fluorescence telescopes is presented. For this technique, a portable, calibrated light source mounted on a rail system is moved across the aperture of each telescope instead of illuminating the whole aperture at once. A dedicated setup using a combination of NIST traceable photodiodes to measure the mean intensity and a PMT for pulse-to-pulse stability tracking has been built for the absolute calibration of the light source. As a result of these complementary measurements, the pulse-to-pulse light source intensity can be known to the 3.5% uncertainty level. The analysis of the readout of the PMT camera at each position of the light source together with the knowledge of the light source emission provides an absolute end-to-end calibration of the telescope. We will give a brief overview of this novel calibration method and its current status as well as show preliminary results from the measurement campaigns performed so far.
The XY scanner – a versatile method of the absolute end-to-end calibration of fluorescence detectors / Schafer, C.M., Abreu, P., Aglietta, M., Albury, J.M., Allekotte, I., Almela, A., Alvarez-Muniz, J., Alves Batista, R., Anastasi, G.A., Anchordoqui, L., Andrada, B., Andringa, S., Aramo, C., Araujo Ferreira, P.R., Arteaga Velazquez, J.C., Asorey, H., Assis, P., Avila, G., Badescu, A.M., Bakalova, A., et al.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - 395:(2022), pp. 1-12. (37th International cosmic ray conference, ICRC 2021 Berlin, Germany ) [10.22323/1.395.0220].
The XY scanner – a versatile method of the absolute end-to-end calibration of fluorescence detectors
Schafer C. M.;Abreu P.;Aglietta M.;Albury J. M.;Allekotte I.;Almela A.;Alvarez-Muniz J.;Alves Batista R.;Anastasi G. A.;Anchordoqui L.;Andrada B.;Andringa S.;Aramo C.;Araujo Ferreira P. R.;Arteaga Velazquez J. C.;Asorey H.;Assis P.;Avila G.;Badescu A. M.;Bakalova A.;Balaceanu A.;Barbato F.;Bar-Reira Luz R. J.;Becker K. H.;Bellido J. A.;Berat C.;Bertaina M. E.;Bertou X.;Biermann P. L.;Binet V.;Bismark K.;Bister T.;Biteau J.;Blazek J.;Bleve C.;Bohacova M.;Boncioli D.;Bonifazi C.;Bonneau Arbeletche L.;Borodai N.;Botti A. M.;Brack J.;Bretz T.;Brichetto Orchera P. G.;Briechle F. L.;Buchholz P.;Bueno A.;Buitink S.;Buscemi M.;Busken M.;Caballero-Mora K. S.;Caccianiga L.;Canfora F.;Caracas I.;Carceller J. M.;Caruso R.;Castellina A.;Catalani F.;Cataldi G.;Cazon L.;Cerda M.;Chinellato J. A.;Chudoba J.;Chytka L.;Clay R. W.;Cobos Cerutti A. C.;Colalillo R.;Coleman A.;Coluccia M. R.;Conceicao R.;Condorelli A.;Consolati G.;Contreras F.;Convenga F.;Correia dos Santos D.;Covault C. E.;Dasso S.;Daumiller K.;Dawson B. R.;Day J. A.;de Almeida R. M.;de Jesus J.;de Jong S. J.;De Mauro G.;de Mello Neto J. R. T.;De Mitri I.;de Oliveira J.;de Oliveira Franco D.;de Palma F.;de Souza V.;De Vito E.;del Rio M.;Deligny O.;Deval L.;di Matteo A.;Dobrigkeit C.;D'Olivo J. C.;Domingues Mendes L. M.;dos Anjos R. C.;dos Santos D.;Dova M. T.;Ebr J.;Engel R.;Epicoco I.;Erdmann M.;Escobar C. O.;Etchegoyen A.;Falcke H.;Farmer J.;Farrar G.;Fauth A. C.;Fazzini N.;Feldbusch F.;Fenu F.;Fick B.;Figueira J. M.;Filipcic A.;Fitoussi T.;Fodran T.;Freire M. M.;Fujii T.;Fuster A.;Galea C.;Galelli C.;Garcia B.;Garcia Vegas A. L.;Gemmeke H.;Gesualdi F.;Gherghel-Lascu A.;Ghia P. L.;Giaccari U.;Giammarchi M.;Glombitza J.;Gobbi F.;Gollan F.;Golup G.;Gomez Berisso M.;Gomez Vitale P. F.;Gongora J. P.;Gonzalez J. M.;Gonzalez N.;Goos I.;Gora D.;Gorgi A.;Gottowik M.;Grubb T. D.;Guarino F.;Guedes G. P.;Guido E.;Hahn S.;Hamal P.;Hampel M. R.;Hansen P.;Harari D.;Harvey V. M.;Haungs A.;Hebbeker T.;Heck D.;Hill G. C.;Hojvat C.;Horandel J. R.;Horvath P.;Hrabovsky M.;Huege T.;Insolia A.;Isar P. G.;Janecek P.;Johnsen J. A.;Jurysek J.;Kaapa A.;Kampert K. H.;Karastathis N.;Keilhauer B.;Kemp J.;Khakurdikar A.;Kizakke Covilakam V. V.;Klages H. O.;Kleifges M.;Kleinfeller J.;Kopke M.;Kunka N.;Lago B. L.;Lang R. G.;Langner N.;Leigui de Oliveira M. A.;Lenok V.;Letessier-Selvon A.;Lhenry-Yvon I.;Lo Presti D.;Lopes L.;Lopez R.;Lu L.;Luce Q.;Lundquist J. P.;Machado Payeras A.;Mancarella G.;Mandat D.;Manning B. C.;Manshanden J.;Mantsch P.;Marafico S.;Mariazzi A. G.;Maris I. C.;Marsella G.;Martello D.;Martinelli S.;Martinez Bravo O.;Mastrodicasa M.;Mathes H. J.;Matthews J.;Matthiae G.;Mayotte E.;Mazur P. O.;Medina-Tanco G.;Melo D.;Menshikov A.;Merenda K. -D.;Michal S.;Micheletti M. I.;Miramonti L.;Mollerach S.;Montanet F.;Morello C.;Mostafa M.;Muller A. L.;Muller M. A.;Mulrey K.;Mussa R.;Muzio M.;Namasaka W. M.;Nasr-Esfahani A.;Nellen L.;Niculescu-Oglinzanu M.;Niechciol M.;Nitz D.;Nosek D.;Novotny V.;Nozka L.;Nucita A.;Nunez L. A.;Palatka M.;Pallotta J.;Papenbreer P.;Parente G.;Parra A.;Pawlowsky J.;Pech M.;Pedreira F.;Pekala J.;Pelayo R.;Pena-Rodriguez J.;Pereira Martins E. E.;Perez Armand J.;Perez Bertolli C.;Perlin M.;Perrone L.;Petrera S.;Pierog T.;Pimenta M.;Pirronello V.;Platino M.;Pont B.;Pothast M.;Privitera P.;Prouza M.;Puyleart A.;Querchfeld S.;Rautenberg J.;Ravignani D.;Reininghaus M.;Ridky J.;Riehn F.;Risse M.;Rizi V.;Rodrigues de Carvalho W.;Rodriguez Rojo J.;Roncoroni M. J.;Rossoni S.;Roth M.;Roulet E.;Rovero A. C.;Ruehl P.;Saftoiu A.;Salamida F.;Salazar H.;Salina G.;Sanabria Gomez J. D.;Sanchez F.;Santos E. M.;Santos E.;Sarazin F.;Sarmento R.;Sarmiento-Cano C.;Sato R.;Savina P.;Schafer C. M.;Scherini V.;Schieler H.;Schimassek M.;Schimp M.;Schluter F.;Schmidt D.;Scholten O.;Schovanek P.;Schroder F. G.;Schroder S.;Schulte J.;Sciutto S. J.;Scornavacche M.;Segreto A.;Sehgal S.;Shellard R. C.;Sigl G.;Silli G.;Sima O.;Smida R.;Sommers P.;Soriano J. F.;Souchard J.;Squartini R.;Stadelmaier M.;Stanca D.;Stanic S.;Stasielak J.;Stassi P.;Streich A.;Suarez-Duran M.;Sudholz T.;Suomijarvi T.;Supanitsky A. D.;Szadkowski Z.;Tapia A.;Taricco C.;Timmermans C.;Tkachenko O.;Tobiska P.;Todero Peixoto C. J.;Tome B.;Torres Z.;Travaini A.;Travnicek P.;Trimarelli C.;Tueros M.;Ulrich R.;Unger M.;Vaclavek L.;Vacula M.;Valdes Galicia J. F.;Valore L.;Varela E.;Vasquez-Ramirez A.;Veberic D.;Ventura C.;Vergara Quispe I. D.;Verzi V.;Vicha J.;Vink J.;Vorobiov S.;Wahlberg H.;Watanabe C.;Watson A. A.;Weber M.;Weindl A.;Wiencke L.;Wilczynski H.;Wirtz M.;Wittkowski D.;Wundheiler B.;Yushkov A.;Zapparrata O.;Zas E.;Zavrtanik D.;Zavrtanik M.;Zehrer L.
2022
Abstract
One of the crucial detector systems of the Pierre Auger Observatory is the fluorescence detector composed of 27 large-aperture wide-angle Schmidt telescopes. In the past, these telescopes were absolutely calibrated by illuminating the whole aperture with a uniform large-diameter light source. This absolute calibration was performed roughly once every three years, while a relative calibration was performed on a nightly basis. In this contribution, a new technique for an absolute end-to-end calibration of the fluorescence telescopes is presented. For this technique, a portable, calibrated light source mounted on a rail system is moved across the aperture of each telescope instead of illuminating the whole aperture at once. A dedicated setup using a combination of NIST traceable photodiodes to measure the mean intensity and a PMT for pulse-to-pulse stability tracking has been built for the absolute calibration of the light source. As a result of these complementary measurements, the pulse-to-pulse light source intensity can be known to the 3.5% uncertainty level. The analysis of the readout of the PMT camera at each position of the light source together with the knowledge of the light source emission provides an absolute end-to-end calibration of the telescope. We will give a brief overview of this novel calibration method and its current status as well as show preliminary results from the measurement campaigns performed so far.
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
5.52 MB
Formato
Adobe PDF
5.52 MB
Adobe PDF
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1752323
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.