An innovative discontinuum-based micromodeling approach, the Applied Element Method, is used in this work to investigate explicitly potential failure mechanisms that might have contributed to the collapse of the Morandi Bridge in Genoa, Italy, which occurred on August 14, 2018. While, consistently with the findings presented in a previous contribution by the same authors, the initial trigger of the collapse mechanism was assumed as the release of one of the stays, this study investigates, through a sensitivity study, the impact that several parameters and epistemic uncertainties, including reduction of cables' cross section (potentially induced by corrosion) and various possible configurations of both passive and active reinforcements in the main deck, have on the predicted failure mode. Then, to indicate the structural elements and details in which a potential presence of corrosion should be more carefully explored, the observed debris distribution is compared with its numerical counterparts.

Numerical Study on the Collapse of the Morandi Bridge / Malomo, D.; Scattarreggia, N.; Orgnoni, A.; Pinho, R.; Moratti, M.; Calvi, G. M.. - In: JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES. - ISSN 0887-3828. - 34:4(2020), p. 04020044. [10.1061/(ASCE)CF.1943-5509.0001428]

Numerical Study on the Collapse of the Morandi Bridge

Malomo D.;Scattarreggia N.;Pinho R.;
2020

Abstract

An innovative discontinuum-based micromodeling approach, the Applied Element Method, is used in this work to investigate explicitly potential failure mechanisms that might have contributed to the collapse of the Morandi Bridge in Genoa, Italy, which occurred on August 14, 2018. While, consistently with the findings presented in a previous contribution by the same authors, the initial trigger of the collapse mechanism was assumed as the release of one of the stays, this study investigates, through a sensitivity study, the impact that several parameters and epistemic uncertainties, including reduction of cables' cross section (potentially induced by corrosion) and various possible configurations of both passive and active reinforcements in the main deck, have on the predicted failure mode. Then, to indicate the structural elements and details in which a potential presence of corrosion should be more carefully explored, the observed debris distribution is compared with its numerical counterparts.
2020
01 Pubblicazione su rivista::01a Articolo in rivista
Numerical Study on the Collapse of the Morandi Bridge / Malomo, D.; Scattarreggia, N.; Orgnoni, A.; Pinho, R.; Moratti, M.; Calvi, G. M.. - In: JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES. - ISSN 0887-3828. - 34:4(2020), p. 04020044. [10.1061/(ASCE)CF.1943-5509.0001428]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1750817
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 67
social impact