Background: An alarming rate of early failure has been recently reported for the LivaNova (previously Sorin) Mitroflow (LivaNova, London, UK) bioprosthesis. Here, we aimed at verifying if this possible underperformance is confirmed in a large, single-center experience and identifying the risk factors associated with early deterioration. Methods: In all, 459 Mitroflow valves have been implanted from July 2009 to December 2013 (patients’ mean age 73 years; 204 women). Surviving patients have undergone yearly clinic and echocardiographic follow-up. Dysfunction was defined as moderate if the mean gradient was more than 30 mm Hg or severe if it exceeded 40 mm Hg. The population was divided on the basis of a dimensional mismatch, the model of the prosthesis (LX or DL: follow-up to 4 years), and patient's age at the time of implantation. Results: Cumulative freedom from moderate valve dysfunction was 81% ± 3% at 60 months. It was lower with patient-prosthesis mismatch (71% ± 5% versus 92% ± 3%; p = 0.0065) and with the more recent DL model (at 42 months: 78% ± 6% versus 96% ± 2%; p < 0.0001). Cumulative freedom from severe dysfunction was 93% ± 2% at 5 years. Again, it was inferior among patients with a mismatch (86% ± 4% versus 100%; p = 0.0013) and for the DL model (42 months: 92.5% ± 3% versus 98.5% ± 1%; p = 0.0309). Smaller prostheses showed higher rates of early degeneration. Conclusions: The LivaNova Mitroflow valve appears to be prone to early deterioration. Smaller size prostheses should be used cautiously and avoided with patient-prosthesis mismatch. The DL model anticalcification treatment seems unable to prevent early degeneration, and possibly contributes to even earlier failure.

An Unexpected Risk Factor for Early Structural Deterioration of Biological Aortic Valve Prostheses / Bassano, C.; Gislao, V.; Bovio, E.; Melino, S.; Tropea, I.; Saitto, G.; Pugliese, M.; Colella, D. F.; Scafuri, A.; Ruvolo, G.. - In: ANNALS OF THORACIC SURGERY. - ISSN 0003-4975. - 105:2(2018), pp. 521-527. [10.1016/j.athoracsur.2017.07.014]

An Unexpected Risk Factor for Early Structural Deterioration of Biological Aortic Valve Prostheses

Saitto G.;Ruvolo G.
2018

Abstract

Background: An alarming rate of early failure has been recently reported for the LivaNova (previously Sorin) Mitroflow (LivaNova, London, UK) bioprosthesis. Here, we aimed at verifying if this possible underperformance is confirmed in a large, single-center experience and identifying the risk factors associated with early deterioration. Methods: In all, 459 Mitroflow valves have been implanted from July 2009 to December 2013 (patients’ mean age 73 years; 204 women). Surviving patients have undergone yearly clinic and echocardiographic follow-up. Dysfunction was defined as moderate if the mean gradient was more than 30 mm Hg or severe if it exceeded 40 mm Hg. The population was divided on the basis of a dimensional mismatch, the model of the prosthesis (LX or DL: follow-up to 4 years), and patient's age at the time of implantation. Results: Cumulative freedom from moderate valve dysfunction was 81% ± 3% at 60 months. It was lower with patient-prosthesis mismatch (71% ± 5% versus 92% ± 3%; p = 0.0065) and with the more recent DL model (at 42 months: 78% ± 6% versus 96% ± 2%; p < 0.0001). Cumulative freedom from severe dysfunction was 93% ± 2% at 5 years. Again, it was inferior among patients with a mismatch (86% ± 4% versus 100%; p = 0.0013) and for the DL model (42 months: 92.5% ± 3% versus 98.5% ± 1%; p = 0.0309). Smaller prostheses showed higher rates of early degeneration. Conclusions: The LivaNova Mitroflow valve appears to be prone to early deterioration. Smaller size prostheses should be used cautiously and avoided with patient-prosthesis mismatch. The DL model anticalcification treatment seems unable to prevent early degeneration, and possibly contributes to even earlier failure.
2018
aortic valve disease; aortic valve replacement; redo surgery
01 Pubblicazione su rivista::01a Articolo in rivista
An Unexpected Risk Factor for Early Structural Deterioration of Biological Aortic Valve Prostheses / Bassano, C.; Gislao, V.; Bovio, E.; Melino, S.; Tropea, I.; Saitto, G.; Pugliese, M.; Colella, D. F.; Scafuri, A.; Ruvolo, G.. - In: ANNALS OF THORACIC SURGERY. - ISSN 0003-4975. - 105:2(2018), pp. 521-527. [10.1016/j.athoracsur.2017.07.014]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1748829
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact