Background: Kinematics experts and physical therapists have implemented the use of sensors for 3D motion analysis, both for static and dynamic movements. XClinic movement sensors are advanced devices designed to analyze movement patterns with high precision. The aim of this study was to validate wearable XClinic sensors for range of motion (ROM) in healthy subjects and obtain normative data. Participants were enrolled at the Sapienza University of Rome in 2024. All participants had to be healthy subjects aged between 18 and 65 years. Data on their demographics, employment and physical activity were collected. All the subjects were tested to assess the active ROM of their shoulder, hip, knee and ankle bilaterally. The same movements were tested using a goniometer to investigate validity, and SF-36 was administered. Fifty subjects were enrolled. The mean age was 28.2 (SD 10.8) years. For the left shoulder, construct validity showed statistically significant values for flexion, extension and extra-rotation, while for the right shoulder, construct validity showed statistically significant values for all movements except intra-rotation. The results concerning the right hip showed statistically significant values for flexion, extra-rotation, intra-rotation and adduction. The left hip showed statistically significant values for all movements except extension. Both the right and left knees showed statistically significant values for flexion. Both the right and left ankles showed statistically significant values for all movements. XClinic sensors offer a reliable and valid solution for the precise monitoring of the ROM of the shoulder and lower limb joints, making them an invaluable asset for clinicians and researchers.

The Innovative XClinic Tool: A Pilot Study Validating Its Precision in Measuring Range of Motion in Healthy Individuals / Galeoto, Giovanni; Ruotolo, Ilaria; Sellitto, Giovanni; Amadio, Emanuele; Di Sipio, Enrica; La Russa, Raffaele; Volonnino, Gianpietro; Frati, Paola. - In: SENSORS. - ISSN 1424-8220. - 25:5(2025), pp. 1-16. [10.3390/s25051331]

The Innovative XClinic Tool: A Pilot Study Validating Its Precision in Measuring Range of Motion in Healthy Individuals

Giovanni Galeoto
Primo
;
Ilaria Ruotolo;Giovanni Sellitto;Emanuele Amadio;Raffaele La Russa;Gianpietro Volonnino;Paola Frati
Ultimo
2025

Abstract

Background: Kinematics experts and physical therapists have implemented the use of sensors for 3D motion analysis, both for static and dynamic movements. XClinic movement sensors are advanced devices designed to analyze movement patterns with high precision. The aim of this study was to validate wearable XClinic sensors for range of motion (ROM) in healthy subjects and obtain normative data. Participants were enrolled at the Sapienza University of Rome in 2024. All participants had to be healthy subjects aged between 18 and 65 years. Data on their demographics, employment and physical activity were collected. All the subjects were tested to assess the active ROM of their shoulder, hip, knee and ankle bilaterally. The same movements were tested using a goniometer to investigate validity, and SF-36 was administered. Fifty subjects were enrolled. The mean age was 28.2 (SD 10.8) years. For the left shoulder, construct validity showed statistically significant values for flexion, extension and extra-rotation, while for the right shoulder, construct validity showed statistically significant values for all movements except intra-rotation. The results concerning the right hip showed statistically significant values for flexion, extra-rotation, intra-rotation and adduction. The left hip showed statistically significant values for all movements except extension. Both the right and left knees showed statistically significant values for flexion. Both the right and left ankles showed statistically significant values for all movements. XClinic sensors offer a reliable and valid solution for the precise monitoring of the ROM of the shoulder and lower limb joints, making them an invaluable asset for clinicians and researchers.
2025
technology; inertial sensors; range of motion; XClinic; psychometric properties
01 Pubblicazione su rivista::01a Articolo in rivista
The Innovative XClinic Tool: A Pilot Study Validating Its Precision in Measuring Range of Motion in Healthy Individuals / Galeoto, Giovanni; Ruotolo, Ilaria; Sellitto, Giovanni; Amadio, Emanuele; Di Sipio, Enrica; La Russa, Raffaele; Volonnino, Gianpietro; Frati, Paola. - In: SENSORS. - ISSN 1424-8220. - 25:5(2025), pp. 1-16. [10.3390/s25051331]
File allegati a questo prodotto
File Dimensione Formato  
Galeoto_Innovative-XClinic-Tool_2025.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 492.58 kB
Formato Adobe PDF
492.58 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1744627
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact