The thermal behaviour of a high thermal inertia ventilated wall made of local bricks in Central Italy is investigated. According to laboratory results, a real scale ventilated facade 8.5 m high was built as a perimeter wall of a gym. The behaviour of the southern facade was monitored continuously for 26 months in different seasons, alternating different openings configurations. Nonventilated, partially ventilated, and ventilated configuration were compared; the wall height influence on the temperatures within the ventilation gap, their phase displacement, and air velocity fields were investigated. Experimental results were used to implement and validate a 2D CFD transient model.
Analysis of the energy performance of a new ventilated brick wall: behaviour of real scale prototype under different ventilation configuration and weather conditions / Fiorini, Costanza Vittoria; Palladino, Domenico; Buratti, Cinzia. - 1:(2022), pp. 2873-2880. ( 17th International Conference of the International Building Performance Simulation Association, Building Simulation 2021 Bruges, Belgium ) [10.26868/25222708.2021.31042].
Analysis of the energy performance of a new ventilated brick wall: behaviour of real scale prototype under different ventilation configuration and weather conditions
Costanza Vittoria Fiorini
Primo
;
2022
Abstract
The thermal behaviour of a high thermal inertia ventilated wall made of local bricks in Central Italy is investigated. According to laboratory results, a real scale ventilated facade 8.5 m high was built as a perimeter wall of a gym. The behaviour of the southern facade was monitored continuously for 26 months in different seasons, alternating different openings configurations. Nonventilated, partially ventilated, and ventilated configuration were compared; the wall height influence on the temperatures within the ventilation gap, their phase displacement, and air velocity fields were investigated. Experimental results were used to implement and validate a 2D CFD transient model.| File | Dimensione | Formato | |
|---|---|---|---|
|
Fiorini_AnalysisOfTheEnergyPerformance_2022.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.63 MB
Formato
Adobe PDF
|
1.63 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.