The association of Morse taper implant-abutment design with the use of a smaller abutment diameter (platform switching) may improve dental implant success rate and prevent peri-implant bone loss. The aim of the present study was to histologically and histomorphometrically evaluate the behavior of peri-implant tissues around an implant with a conical connection associated with platform switching. A platform-switched Morse-cone connection implant was inserted in the left posterior mandible of a 61-year-old patient. The implant was inserted at the level of the alveolar crest. After 11 months from placement and 6 months of loading, the implant was retrieved for psychological reasons and processed for histological evaluation. The retrieved implant was wholly surrounded by bone tissue, except for a small area in the apical portion. At higher magnification, in the coronal portion of the implant, it was possible to observe bone directly at the implant platform level. No resorption of the coronal bone was present, except for 0.2 mm on the vestibular aspect. Crestally, bone remodeling with areas of newly formed bone was detected; the bone-implant contact was 73.9%. Apposition of bone was detected even upon the platform. Peri-implant crestal bone preservation can be achieved with the combination of Morse taper conical internal implant-abutment connection with the use of a smaller abutment diameter (platform-switching).

Histological and histomorphometrical analysis on a loaded implant with platform-switching and conical connection: A case report / Iezzi, Giovanna; Iaculli, Flavia; Calcaterra, Roberta; Piattelli, Adriano; Di Girolamo, Michele; Baggi, Luigi. - In: JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 0160-6972. - 43:3(2017), pp. 180-186. [10.1563/aaid-joi-D-16-00182]

Histological and histomorphometrical analysis on a loaded implant with platform-switching and conical connection: A case report

Iaculli, Flavia;
2017

Abstract

The association of Morse taper implant-abutment design with the use of a smaller abutment diameter (platform switching) may improve dental implant success rate and prevent peri-implant bone loss. The aim of the present study was to histologically and histomorphometrically evaluate the behavior of peri-implant tissues around an implant with a conical connection associated with platform switching. A platform-switched Morse-cone connection implant was inserted in the left posterior mandible of a 61-year-old patient. The implant was inserted at the level of the alveolar crest. After 11 months from placement and 6 months of loading, the implant was retrieved for psychological reasons and processed for histological evaluation. The retrieved implant was wholly surrounded by bone tissue, except for a small area in the apical portion. At higher magnification, in the coronal portion of the implant, it was possible to observe bone directly at the implant platform level. No resorption of the coronal bone was present, except for 0.2 mm on the vestibular aspect. Crestally, bone remodeling with areas of newly formed bone was detected; the bone-implant contact was 73.9%. Apposition of bone was detected even upon the platform. Peri-implant crestal bone preservation can be achieved with the combination of Morse taper conical internal implant-abutment connection with the use of a smaller abutment diameter (platform-switching).
2017
Implant success; Marginal bone loss; Morse taper connection; Platform-switching; Oral Surgery
01 Pubblicazione su rivista::01a Articolo in rivista
Histological and histomorphometrical analysis on a loaded implant with platform-switching and conical connection: A case report / Iezzi, Giovanna; Iaculli, Flavia; Calcaterra, Roberta; Piattelli, Adriano; Di Girolamo, Michele; Baggi, Luigi. - In: JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 0160-6972. - 43:3(2017), pp. 180-186. [10.1563/aaid-joi-D-16-00182]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1737551
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 22
social impact