The increasing use of chiral agrochemicals sold as racemic formulations raises concern for the negative impacts that inactive enantiomers can have on aquatic life and human health. The present work just focuses on the determination of ten chiral pesticides in river water samples by applying a ferrofluid-based microextraction followed by their stereoselective liquid chromatography analysis. To develop the ferrofluid, magnetite nanoparticles were prepared and coated with oleic acid and then dispersed in a hydrophobic natural deep eutectic solvent (NaDES), composed of L-menthol and thymol (1:1). The stable colloidal dispersion was characterised by scanning electron microscopy, thermogravimetric analysis, energy-dispersive X-ray spectroscopy and attenuated total reflection Fourier transform infrared spectroscopy. The analyte microextraction from 5 ml river samples was performed using 50 µl of ferrofluid, while acidified acetonitrile (150 µl) was used to break down the ferrofluid and solubilise the NaDES containing the analytes. All the extracts were analysed by high-performance liquid chromatography-tandem mass spectrometry. For each analyte, the baseline separation of isomers was achieved on a Lux i-Amylose-3 column (amylose tris(3-chloro-5-methylphenylcarbamate) working in reversed-phase mode; the combination with mass spectrometry detection allows the overall separation of 24 isomers (ten chiral analytes among which eight containing a single (one) chiral centre, one with two chiral centres and the last one existing in four stereoisomeric forms, due to the presence of two regioisomers with a chiral carbon) within 37 min. The method showed very good figures of merit in terms of recoveries (77.7–97.5%), intra-day and inter-day precision (2.7–7.7% and 6.9–14.9%, respectively), limit of detection (0.01–0.35 µg/L), limit of quantitation (0.03–1.20 µg/L), linear dynamic range, and intra-day and inter-day accuracy (1.2–14.8% and 1.8–15.0%, respectively). The presented method was able to detect 14 out of 24 isomers at the preventive limit established by the Italian legislation for single pesticide (that for a chiral pesticide is the sum of all its isomers) in surface waters, set at 0.1 µg/l. Finally, the method was evaluated using AGREEprep and ComplexGAPI metrics, compared with other ferrofluid-based methods, and applied to the analysis of water samples from two Italian rivers (the Nera River and the Tiber River), providing to be sustainable and reliable for the application to real river matrices.

Hydrophobic deep eutectic solvent-ferrofluid microextraction followed by liquid chromatography-mass spectrometry for the enantioselective determination of chiral agrochemicals in natural waters / Lucci, Elena; Falcinelli, Gabriele; Antonelli, Lorenzo; Dal Bosco, Chiara; Felli, Nina; De Cesaris, Massimo Giuseppe; Gentili, Alessandra. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - 417:7(2025), pp. 1341-1357. [10.1007/s00216-024-05619-9]

Hydrophobic deep eutectic solvent-ferrofluid microextraction followed by liquid chromatography-mass spectrometry for the enantioselective determination of chiral agrochemicals in natural waters

Lucci, Elena;Falcinelli, Gabriele;Antonelli, Lorenzo;Dal Bosco, Chiara;Felli, Nina;De Cesaris, Massimo Giuseppe;Gentili, Alessandra
2025

Abstract

The increasing use of chiral agrochemicals sold as racemic formulations raises concern for the negative impacts that inactive enantiomers can have on aquatic life and human health. The present work just focuses on the determination of ten chiral pesticides in river water samples by applying a ferrofluid-based microextraction followed by their stereoselective liquid chromatography analysis. To develop the ferrofluid, magnetite nanoparticles were prepared and coated with oleic acid and then dispersed in a hydrophobic natural deep eutectic solvent (NaDES), composed of L-menthol and thymol (1:1). The stable colloidal dispersion was characterised by scanning electron microscopy, thermogravimetric analysis, energy-dispersive X-ray spectroscopy and attenuated total reflection Fourier transform infrared spectroscopy. The analyte microextraction from 5 ml river samples was performed using 50 µl of ferrofluid, while acidified acetonitrile (150 µl) was used to break down the ferrofluid and solubilise the NaDES containing the analytes. All the extracts were analysed by high-performance liquid chromatography-tandem mass spectrometry. For each analyte, the baseline separation of isomers was achieved on a Lux i-Amylose-3 column (amylose tris(3-chloro-5-methylphenylcarbamate) working in reversed-phase mode; the combination with mass spectrometry detection allows the overall separation of 24 isomers (ten chiral analytes among which eight containing a single (one) chiral centre, one with two chiral centres and the last one existing in four stereoisomeric forms, due to the presence of two regioisomers with a chiral carbon) within 37 min. The method showed very good figures of merit in terms of recoveries (77.7–97.5%), intra-day and inter-day precision (2.7–7.7% and 6.9–14.9%, respectively), limit of detection (0.01–0.35 µg/L), limit of quantitation (0.03–1.20 µg/L), linear dynamic range, and intra-day and inter-day accuracy (1.2–14.8% and 1.8–15.0%, respectively). The presented method was able to detect 14 out of 24 isomers at the preventive limit established by the Italian legislation for single pesticide (that for a chiral pesticide is the sum of all its isomers) in surface waters, set at 0.1 µg/l. Finally, the method was evaluated using AGREEprep and ComplexGAPI metrics, compared with other ferrofluid-based methods, and applied to the analysis of water samples from two Italian rivers (the Nera River and the Tiber River), providing to be sustainable and reliable for the application to real river matrices.
2025
Chiral pesticides; Chiral separations; Environmental waters; Ferrofuids; HPLC–MS/MS; Natural deep eutectic solvents
01 Pubblicazione su rivista::01a Articolo in rivista
Hydrophobic deep eutectic solvent-ferrofluid microextraction followed by liquid chromatography-mass spectrometry for the enantioselective determination of chiral agrochemicals in natural waters / Lucci, Elena; Falcinelli, Gabriele; Antonelli, Lorenzo; Dal Bosco, Chiara; Felli, Nina; De Cesaris, Massimo Giuseppe; Gentili, Alessandra. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - 417:7(2025), pp. 1341-1357. [10.1007/s00216-024-05619-9]
File allegati a questo prodotto
File Dimensione Formato  
Lucci_Hydrophobic_2025.pdf

solo gestori archivio

Note: articolo principale
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF   Contatta l'autore
Lucci_supplementary_Hydrophobic_2025.pdf

solo gestori archivio

Note: supplementary information
Tipologia: Altro materiale allegato
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.89 MB
Formato Adobe PDF
1.89 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1736427
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact