Purpose: We aimed to compare the diagnostic yield and procedure-related complications of two different types of systems for percutaneous CT-guided lung biopsy. Material and methods: All patients with a lung lesion who underwent a CT-guided lung biopsy at our institution, between January 2019 and 2021, were retrospectively analyzed. The inclusion criteria were: (a) Procedures performed using either a fully automated tru-cut or a semi-automated full-core biopsy needle, (b) CT images demonstrating the position of the needles within the lesion, (c) histopathological result of the biopsy and (d) clinical follow-up for at least 12 months and\or surgical histopathological results. A total of 400 biopsy fulfilling the inclusion criteria were selected and enrolled in the study. Results: Overall technical success was 100% and diagnostic accuracy was 84%. Tru-cut needles showed a significantly higher diagnostic accuracy when compared to full-core needles (91% vs. 77%, p = 0.0004) and a lower rate of pneumothorax (31% vs. 41%, p = 0.047). Due to the statistically significant different of nodules size between the two groups, we reiterated the statistical analysis splitting our population around the 20 mm cut-off for nodule size. We still observed a significant difference in diagnostic accuracy between tru-cut and full-core needles favoring the former for both smaller and larger lesions (81% vs. 71%, p = 0.025; and 92% vs. 81%; p = 0.01, respectively). Conclusion: Our results demonstrated that the use of automated tru-cut needles is associated with higher histopathological diagnostic accuracy compared to semi-automated full-core needles for CTLB.

Histology profiling of lung tumors: tru-cut versus full-core system for CT-guided biopsies / Tipaldi, MARCELLO ANDREA; Ronconi, Edoardo; Ubaldi, Nicolò; Bozzi, Fernando; Siciliano, Francesco; Zolovkins, Aleksejs; Orgera, Gianluigi; Krokidis, Miltiadis; QUARTA COLOSSO, Giulio; Rossi, Michele. - In: LA RADIOLOGIA MEDICA. - ISSN 1826-6983. - 129:4(2024), pp. 566-574. [10.1007/s11547-024-01772-4]

Histology profiling of lung tumors: tru-cut versus full-core system for CT-guided biopsies

Marcello Andrea Tipaldi
Primo
;
Edoardo Ronconi
Secondo
;
Fernando Bozzi;Francesco Siciliano;Gianluigi Orgera;Giulio Quarta Colosso;Michele Rossi
Ultimo
2024

Abstract

Purpose: We aimed to compare the diagnostic yield and procedure-related complications of two different types of systems for percutaneous CT-guided lung biopsy. Material and methods: All patients with a lung lesion who underwent a CT-guided lung biopsy at our institution, between January 2019 and 2021, were retrospectively analyzed. The inclusion criteria were: (a) Procedures performed using either a fully automated tru-cut or a semi-automated full-core biopsy needle, (b) CT images demonstrating the position of the needles within the lesion, (c) histopathological result of the biopsy and (d) clinical follow-up for at least 12 months and\or surgical histopathological results. A total of 400 biopsy fulfilling the inclusion criteria were selected and enrolled in the study. Results: Overall technical success was 100% and diagnostic accuracy was 84%. Tru-cut needles showed a significantly higher diagnostic accuracy when compared to full-core needles (91% vs. 77%, p = 0.0004) and a lower rate of pneumothorax (31% vs. 41%, p = 0.047). Due to the statistically significant different of nodules size between the two groups, we reiterated the statistical analysis splitting our population around the 20 mm cut-off for nodule size. We still observed a significant difference in diagnostic accuracy between tru-cut and full-core needles favoring the former for both smaller and larger lesions (81% vs. 71%, p = 0.025; and 92% vs. 81%; p = 0.01, respectively). Conclusion: Our results demonstrated that the use of automated tru-cut needles is associated with higher histopathological diagnostic accuracy compared to semi-automated full-core needles for CTLB.
2024
ct-guided; full-core biopsy; image-guided biopsy; lung neoplasms; lung nodules; tru-cut biopsy
01 Pubblicazione su rivista::01a Articolo in rivista
Histology profiling of lung tumors: tru-cut versus full-core system for CT-guided biopsies / Tipaldi, MARCELLO ANDREA; Ronconi, Edoardo; Ubaldi, Nicolò; Bozzi, Fernando; Siciliano, Francesco; Zolovkins, Aleksejs; Orgera, Gianluigi; Krokidis, Miltiadis; QUARTA COLOSSO, Giulio; Rossi, Michele. - In: LA RADIOLOGIA MEDICA. - ISSN 1826-6983. - 129:4(2024), pp. 566-574. [10.1007/s11547-024-01772-4]
File allegati a questo prodotto
File Dimensione Formato  
Tipaldi_Histology_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.09 MB
Formato Adobe PDF
1.09 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1726793
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact