The beam wire scanners of the CERN Super Proton Synchrotron (SPS) experienced multiple failures of their carbon wires caused by the high-intensity beam during a very short period in April 2023. Different modifications of the existing instrument were therefore studied to reduce the beam-induced power without compromising its functionality nor negatively affecting the beam coupling impedance. Amongst these options were the implementation of ferrite absorbers, a change of the scanner mechanism and the installation of an RF coupler in the vacuum tank. In this paper, we introduce the electromagnetic simulation results for the installed ferrite loads and the RF coupler, as well as their impact on the on-axis beam impedance. The final improvement for the configuration to be installed during the end-of-year stop of the accelerator will be summarized.
Mitigation of beam coupling impedance for the wire scanners in the CERN Super Proton Synchrotron / Vollinger, C.; Neroni, M.; Sullivan, M.. - (2024), pp. 3116-3119. (Intervento presentato al convegno 15th International Particle Accelerator Conference tenutosi a Nashville, TN, USA) [10.18429/jacow-ipac2024-thpc51].
Mitigation of beam coupling impedance for the wire scanners in the CERN Super Proton Synchrotron
M. Neroni;
2024
Abstract
The beam wire scanners of the CERN Super Proton Synchrotron (SPS) experienced multiple failures of their carbon wires caused by the high-intensity beam during a very short period in April 2023. Different modifications of the existing instrument were therefore studied to reduce the beam-induced power without compromising its functionality nor negatively affecting the beam coupling impedance. Amongst these options were the implementation of ferrite absorbers, a change of the scanner mechanism and the installation of an RF coupler in the vacuum tank. In this paper, we introduce the electromagnetic simulation results for the installed ferrite loads and the RF coupler, as well as their impact on the on-axis beam impedance. The final improvement for the configuration to be installed during the end-of-year stop of the accelerator will be summarized.File | Dimensione | Formato | |
---|---|---|---|
Vollinger_Mitigation-of-beam_2024.pdf
accesso aperto
Note: Atto di convegno in volume
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.49 MB
Formato
Adobe PDF
|
1.49 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.