The beam wire scanners of the CERN Super Proton Synchrotron (SPS) experienced multiple failures of their carbon wires caused by the high-intensity beam during a very short period in April 2023. Different modifications of the existing instrument were therefore studied to reduce the beam-induced power without compromising its functionality nor negatively affecting the beam coupling impedance. Amongst these options were the implementation of ferrite absorbers, a change of the scanner mechanism and the installation of an RF coupler in the vacuum tank. In this paper, we introduce the electromagnetic simulation results for the installed ferrite loads and the RF coupler, as well as their impact on the on-axis beam impedance. The final improvement for the configuration to be installed during the end-of-year stop of the accelerator will be summarized.

Mitigation of beam coupling impedance for the wire scanners in the CERN Super Proton Synchrotron / Vollinger, C.; Neroni, M.; Sullivan, M.. - (2024), pp. 3116-3119. (Intervento presentato al convegno 15th International Particle Accelerator Conference tenutosi a Nashville, TN, USA) [10.18429/jacow-ipac2024-thpc51].

Mitigation of beam coupling impedance for the wire scanners in the CERN Super Proton Synchrotron

M. Neroni;
2024

Abstract

The beam wire scanners of the CERN Super Proton Synchrotron (SPS) experienced multiple failures of their carbon wires caused by the high-intensity beam during a very short period in April 2023. Different modifications of the existing instrument were therefore studied to reduce the beam-induced power without compromising its functionality nor negatively affecting the beam coupling impedance. Amongst these options were the implementation of ferrite absorbers, a change of the scanner mechanism and the installation of an RF coupler in the vacuum tank. In this paper, we introduce the electromagnetic simulation results for the installed ferrite loads and the RF coupler, as well as their impact on the on-axis beam impedance. The final improvement for the configuration to be installed during the end-of-year stop of the accelerator will be summarized.
2024
15th International Particle Accelerator Conference
wire scanners; beam-induced heating; beam coupling impedance
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Mitigation of beam coupling impedance for the wire scanners in the CERN Super Proton Synchrotron / Vollinger, C.; Neroni, M.; Sullivan, M.. - (2024), pp. 3116-3119. (Intervento presentato al convegno 15th International Particle Accelerator Conference tenutosi a Nashville, TN, USA) [10.18429/jacow-ipac2024-thpc51].
File allegati a questo prodotto
File Dimensione Formato  
Vollinger_Mitigation-of-beam_2024.pdf

accesso aperto

Note: Atto di convegno in volume
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1726778
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact