The analysis of cryogenic detector data is known to be challenging for any experiment. The main difficulty resides in the background rejection since they suffer from the presence of several different pulse shapes which need to be discriminated down to very low signal-to-noise ratio. Background reduction is particularly important for the NUCLEUS experiment [1] whose aim is to produce ultra-low threshold ( around 20 eV) cryogenic detectors to measure coherent elastic neutrino-nucleus scattering at the Chooz nuclear power plant. The low threshold is necessary due to the low nuclear recoil signal produced which is below 1 keV. In this poster the data analysis procedure performed for the NUCLEUS experiment with the DIANA analysis framework [2] is presented along with several software upgrades implemented.

Data analysis of the NUCLEUS experiment with the Diana framework / Del Castello, Giorgio; Null, Null; Abele, H.; Angloher, G.; Bento, A.; Burkhart, J.; Canonica, L.; Cappella, F.; Casali, N.; Cerulli, R.; Cruciani, A.; Del Gallo Roccagiovine, M.; Doblhammer, A.; Dorer, S.; Erhart, A.; Friedl, M.; Garai, A.; Ghete, V. M.; Goupy, C.; Hauff, D.; Jeanneau, F.; Jericha, E.; Kaznacheeva, M.; Kinast, A.; Kluck, H.; Langenkämper, A.; Lasserre, T.; Lhuillier, D.; Mancuso, M.; Martin, R.; Mazzolari, A.; Mazzucato, E.; Neyrial, H.; Nones, C.; Oberauer, L.; Ortmann, T.; Pattavina, L.; Peters, L.; Petricca, Federica; Potzel, W.; Pröbst, F.; Pucci, F.; Reindl, F.; Romagnoni, M.; Rothe, J.; Schermer, N.; Schieck, J.; Schönert, S.; Schwertner, C.; Scola, L.; Soum-Sidikov, G.; Stodolsky, L.; Strauss, R.; Tamisari, M.; Tomei, C.; Vignati, M.; Vivier, M.; Wagner, V.; Wex, A.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - (2024), pp. 1-4. ( International conference on topics in astoparticle and underground physics (TAUP) Vienna ) [10.22323/1.441.0257].

Data analysis of the NUCLEUS experiment with the Diana framework

Del Castello, Giorgio
;
Cappella, F.;Casali, N.;Cruciani, A.;del Gallo Roccagiovine, M.;Vignati, M.;
2024

Abstract

The analysis of cryogenic detector data is known to be challenging for any experiment. The main difficulty resides in the background rejection since they suffer from the presence of several different pulse shapes which need to be discriminated down to very low signal-to-noise ratio. Background reduction is particularly important for the NUCLEUS experiment [1] whose aim is to produce ultra-low threshold ( around 20 eV) cryogenic detectors to measure coherent elastic neutrino-nucleus scattering at the Chooz nuclear power plant. The low threshold is necessary due to the low nuclear recoil signal produced which is below 1 keV. In this poster the data analysis procedure performed for the NUCLEUS experiment with the DIANA analysis framework [2] is presented along with several software upgrades implemented.
2024
International conference on topics in astoparticle and underground physics (TAUP)
data analysis; neutrino; NUCLEUS experiment
04 Pubblicazione in atti di convegno::04c Atto di convegno in rivista
Data analysis of the NUCLEUS experiment with the Diana framework / Del Castello, Giorgio; Null, Null; Abele, H.; Angloher, G.; Bento, A.; Burkhart, J.; Canonica, L.; Cappella, F.; Casali, N.; Cerulli, R.; Cruciani, A.; Del Gallo Roccagiovine, M.; Doblhammer, A.; Dorer, S.; Erhart, A.; Friedl, M.; Garai, A.; Ghete, V. M.; Goupy, C.; Hauff, D.; Jeanneau, F.; Jericha, E.; Kaznacheeva, M.; Kinast, A.; Kluck, H.; Langenkämper, A.; Lasserre, T.; Lhuillier, D.; Mancuso, M.; Martin, R.; Mazzolari, A.; Mazzucato, E.; Neyrial, H.; Nones, C.; Oberauer, L.; Ortmann, T.; Pattavina, L.; Peters, L.; Petricca, Federica; Potzel, W.; Pröbst, F.; Pucci, F.; Reindl, F.; Romagnoni, M.; Rothe, J.; Schermer, N.; Schieck, J.; Schönert, S.; Schwertner, C.; Scola, L.; Soum-Sidikov, G.; Stodolsky, L.; Strauss, R.; Tamisari, M.; Tomei, C.; Vignati, M.; Vivier, M.; Wagner, V.; Wex, A.. - In: POS PROCEEDINGS OF SCIENCE. - ISSN 1824-8039. - (2024), pp. 1-4. ( International conference on topics in astoparticle and underground physics (TAUP) Vienna ) [10.22323/1.441.0257].
File allegati a questo prodotto
File Dimensione Formato  
DelCastello_Data-analysis_2024.pdf

accesso aperto

Note: Atto di convegno su rivista
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 464.13 kB
Formato Adobe PDF
464.13 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1724671
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact