Introduction: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). Objective: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. Methods and results: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. Conclusion: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.
Subcutaneous versus transvenous implantable cardioverter defibrillators in children and young adults: A meta‐analysis / Vetta, Giampaolo; Parlavecchio, Antonio; Magnocavallo, Michele; Valente, Debora; Caminiti, Rodolfo; Polselli, Marco; Vetta, Francesco; Cirone, Donatello; Cauti, FILIPPO MARIA; Crea, Pasquale; Rossi, Pietro; Battista Chierchia, Gian; Bianchi, Stefano; de Asmundis, Carlo; Natale, Andrea; Giovanni Della Rocca, Domenico. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 45:12(2022), pp. 1409-1414. [10.1111/pace.14603]
Subcutaneous versus transvenous implantable cardioverter defibrillators in children and young adults: A meta‐analysis
Michele Magnocavallo;Debora Valente;Marco Polselli;Filippo Maria Cauti;
2022
Abstract
Introduction: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). Objective: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. Methods and results: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. Conclusion: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.