The purpose of this study was to evaluate peri-implant soft tissue response by assessing IL-6, IL-1b and MMP-8 levels in peri-implant crevicular fluid (PICF) around machined vs. laser-microgrooved implants/healing/prosthetic abutments during 1 year of function. Twenty-four patients each received 2 one-stage implants in a split mouth design on the same jaw. In each patient, one implant, one immediate healing, and one prosthetic abutment with a machined surface (M group), and one implant, one immediate healing abutment and one prosthetic abutment with a laser-microgrooved surface (LMS group) were used. PICF sampling, pocket probing depths (PPD) and bleeding on probing (BOP) were assessed at 1, 3, and 12 months. IL-6, IL-1b and MMP-8 levels were determined by specific enzyme-linked immunosorbent assay systems (ELISA). Repeated measure ANOVA was used to run comparisons with groups and between groups months at 1, 3, and 12 months. At 3 and 12 months, the LMS group showed significantly lower PD, BOP and IL-6, IL-1β and MMP-8 levels than the M group (P<.05). This study suggests the presence of more remodeling and/or inflammatory phenomena around implants/ abutments with a machined surface than around implants/abutments with a laser-microgrooved surface.
Influence of abutments surface (machined vs. laser-microgrooved) in soft-tissue response during one year of function: Clinical and biochemical outcomes of a RCT with split-mouth design / Guarnieri, R.; Zanza, A.; Reda, R.; Pagnoni, F.; Abbagnale, R.; Di Nardo, D.; Testarelli, L.. - In: ODOVTOS. - ISSN 2215-3411. - 26:3(2024), pp. 253-265. [10.15517/ijds.2024.59827]
Influence of abutments surface (machined vs. laser-microgrooved) in soft-tissue response during one year of function: Clinical and biochemical outcomes of a RCT with split-mouth design
Guarnieri R.Primo
Writing – Original Draft Preparation
;Zanza A.Secondo
Validation
;Reda R.
Conceptualization
;Abbagnale R.Membro del Collaboration Group
;Di Nardo D.Penultimo
Methodology
;Testarelli L.Ultimo
Supervision
2024
Abstract
The purpose of this study was to evaluate peri-implant soft tissue response by assessing IL-6, IL-1b and MMP-8 levels in peri-implant crevicular fluid (PICF) around machined vs. laser-microgrooved implants/healing/prosthetic abutments during 1 year of function. Twenty-four patients each received 2 one-stage implants in a split mouth design on the same jaw. In each patient, one implant, one immediate healing, and one prosthetic abutment with a machined surface (M group), and one implant, one immediate healing abutment and one prosthetic abutment with a laser-microgrooved surface (LMS group) were used. PICF sampling, pocket probing depths (PPD) and bleeding on probing (BOP) were assessed at 1, 3, and 12 months. IL-6, IL-1b and MMP-8 levels were determined by specific enzyme-linked immunosorbent assay systems (ELISA). Repeated measure ANOVA was used to run comparisons with groups and between groups months at 1, 3, and 12 months. At 3 and 12 months, the LMS group showed significantly lower PD, BOP and IL-6, IL-1β and MMP-8 levels than the M group (P<.05). This study suggests the presence of more remodeling and/or inflammatory phenomena around implants/ abutments with a machined surface than around implants/abutments with a laser-microgrooved surface.File | Dimensione | Formato | |
---|---|---|---|
Guarnieri_Influence-of-Abutments_2024.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
608.31 kB
Formato
Adobe PDF
|
608.31 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.