Within the framework of hybrid geotechnical modelling, the coupled centrifuge-numerical modelling (CCNM) technique, developed at the University of Nottingham Centre for Geomechanics (NCG), is becoming a well-established approach to study the interaction between tunnel excavation, related soil movements, and induced response of affected structures. The CCNM technique involves a centrifuge model that includes the tunnel, soil, and foundation system, and a parallel finite element numerical model schematising the structure. Displacement and loading data at the structure-foundation interface are shared between the centrifuge and numerical domains in “real-time”, such that a global evaluation of the interactions occurring can be captured for buildings that require a higher level of detail to be fully described. This study focused on the application of CCNM technology to the analysis of a 2D bare frame with separate strip footings running parallel to the tunnel axis. The frame geometry is consistent with previous “conventional” centrifuge tests (i.e. not hybrid), involving a small-scale physical model of the building. As such, the presented CCNM test aims to provide benchmark data to validate the hybrid modelling method before considering frame configurations with infills. The findings are presented for a case in which the foundation rests on the soil surface.

Response of framed buildings on separate footings to tunnelling: a hybrid modelling study / Spaggiari, Chiara; Tang, Chuajin; Boldini, Daniela; M. Marshall., Alec. - (2024). (Intervento presentato al convegno 5th European Conference on Physical Modelling in Geotechnics tenutosi a Delft; the Netherlands) [10.53243/ECPMG2024-23].

Response of framed buildings on separate footings to tunnelling: a hybrid modelling study

Chiara Spaggiari;Daniela Boldini;
2024

Abstract

Within the framework of hybrid geotechnical modelling, the coupled centrifuge-numerical modelling (CCNM) technique, developed at the University of Nottingham Centre for Geomechanics (NCG), is becoming a well-established approach to study the interaction between tunnel excavation, related soil movements, and induced response of affected structures. The CCNM technique involves a centrifuge model that includes the tunnel, soil, and foundation system, and a parallel finite element numerical model schematising the structure. Displacement and loading data at the structure-foundation interface are shared between the centrifuge and numerical domains in “real-time”, such that a global evaluation of the interactions occurring can be captured for buildings that require a higher level of detail to be fully described. This study focused on the application of CCNM technology to the analysis of a 2D bare frame with separate strip footings running parallel to the tunnel axis. The frame geometry is consistent with previous “conventional” centrifuge tests (i.e. not hybrid), involving a small-scale physical model of the building. As such, the presented CCNM test aims to provide benchmark data to validate the hybrid modelling method before considering frame configurations with infills. The findings are presented for a case in which the foundation rests on the soil surface.
2024
5th European Conference on Physical Modelling in Geotechnics
coupled centrifuge-numerical modelling (CCNM); frame building; soil-structure interaction; tunnel; centrifuge testing
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Response of framed buildings on separate footings to tunnelling: a hybrid modelling study / Spaggiari, Chiara; Tang, Chuajin; Boldini, Daniela; M. Marshall., Alec. - (2024). (Intervento presentato al convegno 5th European Conference on Physical Modelling in Geotechnics tenutosi a Delft; the Netherlands) [10.53243/ECPMG2024-23].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1721104
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact