Objectives: In this study, we establish a protocol for evaluating the outcomes of endothelial keratoplasty, including graft survival, rejection, or failure. Additionally, we also evaluate the alloimmune response in graft recipients. Methods: We performed EK using C57BL/6 (allogeneic) and BALB/c (syngeneic) as donors and BALB/c mice as recipients. Slit-lamp examination and optical coherence tomography were performed for clinical evaluations for 16 weeks post-procedure. Criteria for the assessment of corneal opacity were established and the animals were graded weekly. Additionally, we assessed corneal endothelial cell density by harvesting the corneas and staining with zonula occludens-1 (ZO-1). Lastly, lymph nodes were collected, and CD4+ T cells were MACS-sorted and co-cultured with syngeneic or allogeneic antigen-presenting cells (APCs) to assess the IFN-γ expression levels by alloreactive Th1 cells (ELISPOT) in response to the direct (donor) or indirect (host) pathways of sensitization. Results: We observed graft failure in four animals, including irreversible corneal opacity, graft detachment, and anterior synechiae in the first four weeks. The remaining animals were graded between 0 and 5 as per the established criteria. The total and graft corneal thickness and endothelial cell density progressively worsened with a higher grade of corneal opacity. The direct allosensitization of Th1 cells was significantly higher in mice with a higher grade of corneal opacity. At 16 weeks follow-up, the grafts remained stable with low opacity scores in syngeneic EK recipients; however, the opacity scores were higher and variable in allogeneic EK recipients. Conclusions: These findings establish a standardized protocol to assess the graft outcomes in a murine model of EK. Furthermore, we delineate the underlying immunological pathway that contributes to the immune-mediated rejection of grafts in this model.

Assessment of corneal graft outcomes in a murine model of endothelial keratoplasty / Narimatsu, Akitomo; Singh, Rohan Bir; Surico, Pier Luigi; Lee, Seokjoo; Forouzanfar, Katayoon; Kahale, Francesca; Musayeva, Aytan; Dohlman, Thomas H; Blanco, Tomas; Dana, Reza. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:17(2024), pp. 1-12. [10.3390/jcm13175010]

Assessment of corneal graft outcomes in a murine model of endothelial keratoplasty

Surico, Pier Luigi
Writing – Review & Editing
;
2024

Abstract

Objectives: In this study, we establish a protocol for evaluating the outcomes of endothelial keratoplasty, including graft survival, rejection, or failure. Additionally, we also evaluate the alloimmune response in graft recipients. Methods: We performed EK using C57BL/6 (allogeneic) and BALB/c (syngeneic) as donors and BALB/c mice as recipients. Slit-lamp examination and optical coherence tomography were performed for clinical evaluations for 16 weeks post-procedure. Criteria for the assessment of corneal opacity were established and the animals were graded weekly. Additionally, we assessed corneal endothelial cell density by harvesting the corneas and staining with zonula occludens-1 (ZO-1). Lastly, lymph nodes were collected, and CD4+ T cells were MACS-sorted and co-cultured with syngeneic or allogeneic antigen-presenting cells (APCs) to assess the IFN-γ expression levels by alloreactive Th1 cells (ELISPOT) in response to the direct (donor) or indirect (host) pathways of sensitization. Results: We observed graft failure in four animals, including irreversible corneal opacity, graft detachment, and anterior synechiae in the first four weeks. The remaining animals were graded between 0 and 5 as per the established criteria. The total and graft corneal thickness and endothelial cell density progressively worsened with a higher grade of corneal opacity. The direct allosensitization of Th1 cells was significantly higher in mice with a higher grade of corneal opacity. At 16 weeks follow-up, the grafts remained stable with low opacity scores in syngeneic EK recipients; however, the opacity scores were higher and variable in allogeneic EK recipients. Conclusions: These findings establish a standardized protocol to assess the graft outcomes in a murine model of EK. Furthermore, we delineate the underlying immunological pathway that contributes to the immune-mediated rejection of grafts in this model.
2024
endothelial keratoplasty; graft failure; graft rejection; murine model
01 Pubblicazione su rivista::01a Articolo in rivista
Assessment of corneal graft outcomes in a murine model of endothelial keratoplasty / Narimatsu, Akitomo; Singh, Rohan Bir; Surico, Pier Luigi; Lee, Seokjoo; Forouzanfar, Katayoon; Kahale, Francesca; Musayeva, Aytan; Dohlman, Thomas H; Blanco, Tomas; Dana, Reza. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:17(2024), pp. 1-12. [10.3390/jcm13175010]
File allegati a questo prodotto
File Dimensione Formato  
Narimatsu_Assessment of corneal_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.6 MB
Formato Adobe PDF
2.6 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1720357
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact