The present paper describes a fast and reproducible procedure, employing differential pulse stripping analysis technique with graphite microelectrodes, for the quantitative evaluation of the ionic fraction of heavy metals (namely Hg, Cu, and Zn) released from dental amalgams into synthetic saliva during 6–90 h contact between amalgam and saliva, after completion of the dental restoration (short-term release). The Zn2+ concentration was evaluated by linear calibration, whereas Cu2+ and Hg2+ contents were estimated by the standard additions method. While the concentration of Zn2+ ion does not increase significantly anymore after a 6-h contact (values from 288±12 to 346±12 μg dm−3 at time of contact from 6 to 90 h, respectively), in the same time interval the concentration of both Cu2+ and Hg2+ ions progressively increases (from 38±6 to 197±4 μg dm−3 and from 15±3 to 101±2 μg dm−3, respectively). The results of the release tests reveal that Hg concentration is at the highest level of risk (HBM III), as identified by the three human biomonitoring categories suggested by the Institut für Wasser-, Boden- und Lufthygiene des Umweltbundesamtes (Germany) for the estimation of potential harmful effects on health due to exposure to heavy metals.

Study on the Short-Term Release of Heavy Metals From Dental Amalgam into Saliva by Anodic Stripping Voltammetry with Microelectrodes / Sanna, Gavino; Pilo, Maria Itria; Piu, Paola Costantina; Spano, Nadia; Tapparo, A.; Campus, Guglielmo Giuseppe; Seeber, R.. - In: TALANTA. - ISSN 0039-9140. - 58:(2002), pp. 979-985. [10.1016/S0039-9140(02)00454-X]

Study on the Short-Term Release of Heavy Metals From Dental Amalgam into Saliva by Anodic Stripping Voltammetry with Microelectrodes

CAMPUS, Guglielmo Giuseppe;
2002

Abstract

The present paper describes a fast and reproducible procedure, employing differential pulse stripping analysis technique with graphite microelectrodes, for the quantitative evaluation of the ionic fraction of heavy metals (namely Hg, Cu, and Zn) released from dental amalgams into synthetic saliva during 6–90 h contact between amalgam and saliva, after completion of the dental restoration (short-term release). The Zn2+ concentration was evaluated by linear calibration, whereas Cu2+ and Hg2+ contents were estimated by the standard additions method. While the concentration of Zn2+ ion does not increase significantly anymore after a 6-h contact (values from 288±12 to 346±12 μg dm−3 at time of contact from 6 to 90 h, respectively), in the same time interval the concentration of both Cu2+ and Hg2+ ions progressively increases (from 38±6 to 197±4 μg dm−3 and from 15±3 to 101±2 μg dm−3, respectively). The results of the release tests reveal that Hg concentration is at the highest level of risk (HBM III), as identified by the three human biomonitoring categories suggested by the Institut für Wasser-, Boden- und Lufthygiene des Umweltbundesamtes (Germany) for the estimation of potential harmful effects on health due to exposure to heavy metals.
2002
Microelectrodes; Stripping analysis; Mercury determination; Synthetic saliva
01 Pubblicazione su rivista::01a Articolo in rivista
Study on the Short-Term Release of Heavy Metals From Dental Amalgam into Saliva by Anodic Stripping Voltammetry with Microelectrodes / Sanna, Gavino; Pilo, Maria Itria; Piu, Paola Costantina; Spano, Nadia; Tapparo, A.; Campus, Guglielmo Giuseppe; Seeber, R.. - In: TALANTA. - ISSN 0039-9140. - 58:(2002), pp. 979-985. [10.1016/S0039-9140(02)00454-X]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1719275
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 16
social impact