This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within ~1–2 MeV/c, a relative beam energy spread below 0.25%, and an absolute precision in the intensity of the beam at the level of 2%.

Characterization of the PADME positron beam for the X17 measurement / Bertelli, S.; Bossi, F.; Buonomo, B.; De Sangro, R.; Di Giulio, C.; Di Meco, E.; Dimitrova, K.; Domenici, D.; Ferrarotto, F.; Finocchiaro, G.; Foggetta, L. G.; Frankenthal, A.; Garattini, M.; Georgiev, G.; Gianotti, P.; Ivanov, S.; Ivanov, S.; Kozhuharov, V.; Leonardi, E.; Long, E.; Mancini, M.; Organtini, G. C.; Raggi, M.; Sarra, I.; Simeonov, R.; Spadaro, T.; Spiriti, E.; Valente, P.; Variola, A.; Vilucchi, E.. - In: JOURNAL OF HIGH ENERGY PHYSICS. - ISSN 1029-8479. - 2024:8(2024). [10.1007/JHEP08(2024)121]

Characterization of the PADME positron beam for the X17 measurement

Di Meco E.;Kozhuharov V.;Long E.;Raggi M.;
2024

Abstract

This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within ~1–2 MeV/c, a relative beam energy spread below 0.25%, and an absolute precision in the intensity of the beam at the level of 2%.
2024
Beyond Standard Model; Dark Matter; Exotics; Fixed Target Experiments
01 Pubblicazione su rivista::01a Articolo in rivista
Characterization of the PADME positron beam for the X17 measurement / Bertelli, S.; Bossi, F.; Buonomo, B.; De Sangro, R.; Di Giulio, C.; Di Meco, E.; Dimitrova, K.; Domenici, D.; Ferrarotto, F.; Finocchiaro, G.; Foggetta, L. G.; Frankenthal, A.; Garattini, M.; Georgiev, G.; Gianotti, P.; Ivanov, S.; Ivanov, S.; Kozhuharov, V.; Leonardi, E.; Long, E.; Mancini, M.; Organtini, G. C.; Raggi, M.; Sarra, I.; Simeonov, R.; Spadaro, T.; Spiriti, E.; Valente, P.; Variola, A.; Vilucchi, E.. - In: JOURNAL OF HIGH ENERGY PHYSICS. - ISSN 1029-8479. - 2024:8(2024). [10.1007/JHEP08(2024)121]
File allegati a questo prodotto
File Dimensione Formato  
Bertelli_Characterization _2024.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.48 MB
Formato Adobe PDF
3.48 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1718232
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact