Background: Physiological patterns of coronary artery disease (CAD) have emerged as potential determinants of functional results of percutaneous coronary interventions (PCI) and of vessel-oriented clinical outcomes (VOCE). Objectives: In this study, we evaluated the impact of angiography-derived physiological patterns of CAD on post-PCI functional results and long-term clinical outcomes. Methods: Pre-PCI angiography-derived fractional flow reserve (FFR) virtual pullbacks were quantitatively interpreted and used to determine the physiological patterns of CAD. Suboptimal post-PCI physiology was defined as an angiography-derived FFR value ≤ 0.91. The primary endpoint was the occurrence of VOCE at the longest available follow-up. Results: Six hundred fifteen lesions from 516 patients were stratified into predominantly focal (n = 322, 52.3%) and predominantly diffuse (n = 293, 47.7%). Diffuse pattern of CAD was associated with lower post-PCI angiography-derived FFR values (0.91 ± 0.05 vs. 0.94 ± 0.05; p = 0.001) and larger rate of suboptimal post-PCI physiology (43.0 vs. 22.7%; p = 0.001), as compared to focal CAD. At the median follow-up time of 37 months (33-58), post-PCI suboptimal physiology was related to a higher risk of VOCE (16.2% vs. 7.6%; HR: 2.311; 95% CI 1.410-3.794; p = 0.0009), while no significant difference was noted according to baseline physiological pattern. In diffuse disease, the use of intracoronary imaging was associated with a lower incidence of long-term VOCE (5.1% vs 14.8%; HR: 0.313, 95% CI 0.167-0.614, p = 0.030). Conclusions: Suboptimal post-PCI physiology is observed more often in diffusely diseased arteries and it is associated with higher risk of VOCE at follow-up. The use of intravascular imaging might improve clinical outcomes in the setting of diffuse CAD.

Angiography-derived physiological patterns of coronary artery disease: implications with post-stenting physiology and long-term clinical outcomes / Fezzi, S., Del Sole, P.A., Burzotta, F., Leone, A.M., Ding, D., Terentes-Printzios, D., Trani, C., Bonizzi, L., Sgreva, S., Andreaggi, S., Huang, J., Pesarini, G., Tavella, D., Prado, G., Vicerè, A., Oikonomou, D., Gkini, K.P., Galante, D., Tsioufis, K., Vlachopoulos, C., et al.. - In: CLINICAL RESEARCH IN CARDIOLOGY. - ISSN 1861-0684. - (2024). [10.1007/s00392-024-02500-8]

Angiography-derived physiological patterns of coronary artery disease: implications with post-stenting physiology and long-term clinical outcomes

Prado, Guy;
2024

Abstract

Background: Physiological patterns of coronary artery disease (CAD) have emerged as potential determinants of functional results of percutaneous coronary interventions (PCI) and of vessel-oriented clinical outcomes (VOCE). Objectives: In this study, we evaluated the impact of angiography-derived physiological patterns of CAD on post-PCI functional results and long-term clinical outcomes. Methods: Pre-PCI angiography-derived fractional flow reserve (FFR) virtual pullbacks were quantitatively interpreted and used to determine the physiological patterns of CAD. Suboptimal post-PCI physiology was defined as an angiography-derived FFR value ≤ 0.91. The primary endpoint was the occurrence of VOCE at the longest available follow-up. Results: Six hundred fifteen lesions from 516 patients were stratified into predominantly focal (n = 322, 52.3%) and predominantly diffuse (n = 293, 47.7%). Diffuse pattern of CAD was associated with lower post-PCI angiography-derived FFR values (0.91 ± 0.05 vs. 0.94 ± 0.05; p = 0.001) and larger rate of suboptimal post-PCI physiology (43.0 vs. 22.7%; p = 0.001), as compared to focal CAD. At the median follow-up time of 37 months (33-58), post-PCI suboptimal physiology was related to a higher risk of VOCE (16.2% vs. 7.6%; HR: 2.311; 95% CI 1.410-3.794; p = 0.0009), while no significant difference was noted according to baseline physiological pattern. In diffuse disease, the use of intracoronary imaging was associated with a lower incidence of long-term VOCE (5.1% vs 14.8%; HR: 0.313, 95% CI 0.167-0.614, p = 0.030). Conclusions: Suboptimal post-PCI physiology is observed more often in diffusely diseased arteries and it is associated with higher risk of VOCE at follow-up. The use of intravascular imaging might improve clinical outcomes in the setting of diffuse CAD.
2024
angiography-derived physiology; intracoronary imaging; percutaneous coronary intervention; physiological pattern of coronary disease; quantitative flow ratio
01 Pubblicazione su rivista::01a Articolo in rivista
Angiography-derived physiological patterns of coronary artery disease: implications with post-stenting physiology and long-term clinical outcomes / Fezzi, S., Del Sole, P.A., Burzotta, F., Leone, A.M., Ding, D., Terentes-Printzios, D., Trani, C., Bonizzi, L., Sgreva, S., Andreaggi, S., Huang, J., Pesarini, G., Tavella, D., Prado, G., Vicerè, A., Oikonomou, D., Gkini, K.P., Galante, D., Tsioufis, K., Vlachopoulos, C., et al.. - In: CLINICAL RESEARCH IN CARDIOLOGY. - ISSN 1861-0684. - (2024). [10.1007/s00392-024-02500-8]
File allegati a questo prodotto
File Dimensione Formato  
Fezzi_Angiography‑derived-physiological_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1717118
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 14
social impact