We evaluate the performance of a lab-on-chip optoelectronic device made with a polymeric waveguide and a hydrogenated amorphous silicon (a-Si:H) photodetector. Both components are integrated onto a compact BK7 glass substrate with a small surface area. The device is designed to measure the analyte concentration in a sample by detecting changes in light power caused by the interaction between the solution droplet and the guided radiation. This power variation is related to the sample's refractive index and is detected by an a-Si:H photosensor. Through numerical simulations in the red spectrum (632.8 nm), we assess the device's efficiency for detecting zinc (Zn) and lead (Pb). We analyze the interaction between the sample and the chip in various conditions and combine these findings with experimental data on the a-Si:H detector's performance. Our results indicate that the sensor exhibits a sensitivity down to 16.6 pA/ppm for Zn and 16.2 pA/ppm for Pb, with detection limits of 9.8 ppb for Zn and 10 ppb for Pb. This compact, cost-effective, and user-friendly chip demonstrates promising performance for applications in health and environmental monitoring, particularly in detecting heavy metals in water in real-time.

Sub-ppm photonic biosensor for water quality control: feasibility study on zinc and lead detection / Alaeddini, A.; Buzzin, A.; Asquini, R.; Caputo, D.; de Cesare, and G.. - (2024), pp. 30-31. (Intervento presentato al convegno AISEM 2024 - XXII Annual Conference on Sensors and Microsystems tenutosi a Bologna).

Sub-ppm photonic biosensor for water quality control: feasibility study on zinc and lead detection

A. Alaeddini;A. Buzzin;R. Asquini;D. Caputo;and G. de Cesare
2024

Abstract

We evaluate the performance of a lab-on-chip optoelectronic device made with a polymeric waveguide and a hydrogenated amorphous silicon (a-Si:H) photodetector. Both components are integrated onto a compact BK7 glass substrate with a small surface area. The device is designed to measure the analyte concentration in a sample by detecting changes in light power caused by the interaction between the solution droplet and the guided radiation. This power variation is related to the sample's refractive index and is detected by an a-Si:H photosensor. Through numerical simulations in the red spectrum (632.8 nm), we assess the device's efficiency for detecting zinc (Zn) and lead (Pb). We analyze the interaction between the sample and the chip in various conditions and combine these findings with experimental data on the a-Si:H detector's performance. Our results indicate that the sensor exhibits a sensitivity down to 16.6 pA/ppm for Zn and 16.2 pA/ppm for Pb, with detection limits of 9.8 ppb for Zn and 10 ppb for Pb. This compact, cost-effective, and user-friendly chip demonstrates promising performance for applications in health and environmental monitoring, particularly in detecting heavy metals in water in real-time.
2024
AISEM 2024 - XXII Annual Conference on Sensors and Microsystems
04 Pubblicazione in atti di convegno::04d Abstract in atti di convegno
Sub-ppm photonic biosensor for water quality control: feasibility study on zinc and lead detection / Alaeddini, A.; Buzzin, A.; Asquini, R.; Caputo, D.; de Cesare, and G.. - (2024), pp. 30-31. (Intervento presentato al convegno AISEM 2024 - XXII Annual Conference on Sensors and Microsystems tenutosi a Bologna).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1716539
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact