Introduction and Objectives: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron (TM) sirolimus-eluting stent (SES) with the control Biomatrix (TM) Flex biolirms-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure.Methods: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization.Results: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group.Conclusions: The novel Inspiron (TM) stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix (TM) Flex biolimus-eluting stent. (C) 2020 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.

Comparative clinical performance of two types of drug-eluting stents with abluminal biodegradable polymer coating: Five-year results of the DESTINY randomized trial / Prado Jr, Guy F. A.; Abizaid, Alexandre A. C.; Meireles, George C.; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D.; Jose Mariani, Jr; Perin, Marco A.; Costantini, Costantino; Costa, Ricardo; Costa, J. Ribamar; Chamie, Daniel; Campos, Carlos M.; Ribeiro, Expedito E.; Lemos, Pedro A.. - In: REVISTA PORTUGUESA DE CARDIOLOGIA. - ISSN 0870-2551. - 40:2(2021), pp. 71-76. [10.1016/j.repc.2020.05.017]

Comparative clinical performance of two types of drug-eluting stents with abluminal biodegradable polymer coating: Five-year results of the DESTINY randomized trial

Prado Jr, Guy F. A.
Primo
;
2021

Abstract

Introduction and Objectives: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron (TM) sirolimus-eluting stent (SES) with the control Biomatrix (TM) Flex biolirms-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure.Methods: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization.Results: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group.Conclusions: The novel Inspiron (TM) stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix (TM) Flex biolimus-eluting stent. (C) 2020 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espana, S.L.U.
2021
biodegradable polymers; drug-eluting stent; intravascular ultrasound; optical coherence tomography
01 Pubblicazione su rivista::01a Articolo in rivista
Comparative clinical performance of two types of drug-eluting stents with abluminal biodegradable polymer coating: Five-year results of the DESTINY randomized trial / Prado Jr, Guy F. A.; Abizaid, Alexandre A. C.; Meireles, George C.; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D.; Jose Mariani, Jr; Perin, Marco A.; Costantini, Costantino; Costa, Ricardo; Costa, J. Ribamar; Chamie, Daniel; Campos, Carlos M.; Ribeiro, Expedito E.; Lemos, Pedro A.. - In: REVISTA PORTUGUESA DE CARDIOLOGIA. - ISSN 0870-2551. - 40:2(2021), pp. 71-76. [10.1016/j.repc.2020.05.017]
File allegati a questo prodotto
File Dimensione Formato  
Prado_Comparative-clinical-performance_2021.pdf

accesso aperto

Note: Versione in press
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 610.62 kB
Formato Adobe PDF
610.62 kB Adobe PDF
Prado_Comparative-clinical-performance_2021.pdf

accesso aperto

Note: Versione definitiva
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 628.71 kB
Formato Adobe PDF
628.71 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1716297
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact