Objectives: Use of ultrasonography has been suggested as an accurate adjunct to clinical evaluation of fetal position and station during labor. There are no available reports concerning its actual use in delivery wards. The aim of this survey was to evaluate the current practice regarding the use of ultrasonography during labor. Methods: A questionnaire was sent to members of the Italian Society of Ultrasound in Obstetrics and Gynecology employed in delivery wards. The qFeuestionnaire was made up of 22 questions evaluating participant characteristics and the current use of ultrasound in labor in their hospital of employment. The answers were grouped according to participant characteristics. Results: A total of 200 participants replied. Ultrasound was considered useful before an operative vaginal delivery by 59.6 % of respondents, while 51.8 and 52.5 % considered it useful in the management of prolonged first and second stages of labor, respectively. The major indication for ultrasound use during labor was the assessment of fetal occiput position. The major difficulties in its application were the perceived lack of training and the complexity of the ultrasound equipment use. Participants that reported fewer difficulties were those employed in hospitals with a higher number of deliveries or having delivery units with more years of experience using ultrasound in labor, or those who had attended specific training courses. Conclusions: The results indicate that, despite the reported evidence of a higher accuracy of ultrasound compared to clinical evaluation in assessing fetal position and station, its use is still limited, even amongst maternal-fetal medicine practitioners specialized in ultrasonography.
A national survey on current practice of ultrasound in labor ward / Mappa, Ilenia; Masturzo, Bianca; Carbone, Ilma Floriana; Kiener, Ariane; Maruotti, Giuseppe Maria; Pintucci, Armando; Suprani, Alice; Visentin, Silvia; Ghi, Tullio; Rizzo, Giuseppe. - In: JOURNAL OF PERINATAL MEDICINE. - ISSN 1619-3997. - 52:5(2024). [10.1515/jpm-2024-0057]
A national survey on current practice of ultrasound in labor ward
Rizzo, Giuseppe
2024
Abstract
Objectives: Use of ultrasonography has been suggested as an accurate adjunct to clinical evaluation of fetal position and station during labor. There are no available reports concerning its actual use in delivery wards. The aim of this survey was to evaluate the current practice regarding the use of ultrasonography during labor. Methods: A questionnaire was sent to members of the Italian Society of Ultrasound in Obstetrics and Gynecology employed in delivery wards. The qFeuestionnaire was made up of 22 questions evaluating participant characteristics and the current use of ultrasound in labor in their hospital of employment. The answers were grouped according to participant characteristics. Results: A total of 200 participants replied. Ultrasound was considered useful before an operative vaginal delivery by 59.6 % of respondents, while 51.8 and 52.5 % considered it useful in the management of prolonged first and second stages of labor, respectively. The major indication for ultrasound use during labor was the assessment of fetal occiput position. The major difficulties in its application were the perceived lack of training and the complexity of the ultrasound equipment use. Participants that reported fewer difficulties were those employed in hospitals with a higher number of deliveries or having delivery units with more years of experience using ultrasound in labor, or those who had attended specific training courses. Conclusions: The results indicate that, despite the reported evidence of a higher accuracy of ultrasound compared to clinical evaluation in assessing fetal position and station, its use is still limited, even amongst maternal-fetal medicine practitioners specialized in ultrasonography.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.