Background: Buried free flaps represent a reconstructive challenge concerning monitoring of vitality, which is fundamental for an early detection of flap failure and prompt surgical salvage. Many flap monitoring techniques have been developed over time, and there is still no consensus concerning the best monitoring technique for buried reconstructions. Methods: We performed a systematic review of the literature on NIRS monitoring for head and neck free flaps. Moreover, we presented a case of orbital reconstruction through a buried free myo-fascial anterolateral tight flap (ALTF) in which postoperative monitoring was performed by means of NIRS. Results: Four studies were included with a total of 200 monitored head and neck free flap reconstructions. Flap survival was reported in 96.5% of studies (n = 193/200) with a 3.5% of total flap failure rate (n = 7/200). We monitored the buried myo-fascial ALTF for 7 post-operative days measuring a regional oxygen saturation (rSO(2)) ranging from 55% to 72% (mean = 66%). Conclusions:This device appeared to be an efficient choice for monitoring buried flaps, thanks to its ability to measure tissue perfusion deep under the skin, to the continuous availability of recorded data on the monitor, and to its low impact on the patient. Further prospective studies are advised in order to standardize this monitoring technique and define warning values.

Near-infrared spectroscopy for continuous noninvasive monitoring of free flap in head and neck reconstruction: systematic review of the literature and personal experience / Festa, Bianca Maria; Costantino, Andrea; Pace, Gian Marco; Spriano, Giuseppe; De Virgilio, Armando. - In: SURGICAL INNOVATION. - ISSN 1553-3514. - 30:6(2023), pp. 711-719. [10.1177/15533506231209128]

Near-infrared spectroscopy for continuous noninvasive monitoring of free flap in head and neck reconstruction: systematic review of the literature and personal experience

De Virgilio, Armando
Ultimo
Supervision
2023

Abstract

Background: Buried free flaps represent a reconstructive challenge concerning monitoring of vitality, which is fundamental for an early detection of flap failure and prompt surgical salvage. Many flap monitoring techniques have been developed over time, and there is still no consensus concerning the best monitoring technique for buried reconstructions. Methods: We performed a systematic review of the literature on NIRS monitoring for head and neck free flaps. Moreover, we presented a case of orbital reconstruction through a buried free myo-fascial anterolateral tight flap (ALTF) in which postoperative monitoring was performed by means of NIRS. Results: Four studies were included with a total of 200 monitored head and neck free flap reconstructions. Flap survival was reported in 96.5% of studies (n = 193/200) with a 3.5% of total flap failure rate (n = 7/200). We monitored the buried myo-fascial ALTF for 7 post-operative days measuring a regional oxygen saturation (rSO(2)) ranging from 55% to 72% (mean = 66%). Conclusions:This device appeared to be an efficient choice for monitoring buried flaps, thanks to its ability to measure tissue perfusion deep under the skin, to the continuous availability of recorded data on the monitor, and to its low impact on the patient. Further prospective studies are advised in order to standardize this monitoring technique and define warning values.
2023
buried flap; flap monitoring; free flap; near-infrared spectroscopy; reconstruction
01 Pubblicazione su rivista::01a Articolo in rivista
Near-infrared spectroscopy for continuous noninvasive monitoring of free flap in head and neck reconstruction: systematic review of the literature and personal experience / Festa, Bianca Maria; Costantino, Andrea; Pace, Gian Marco; Spriano, Giuseppe; De Virgilio, Armando. - In: SURGICAL INNOVATION. - ISSN 1553-3514. - 30:6(2023), pp. 711-719. [10.1177/15533506231209128]
File allegati a questo prodotto
File Dimensione Formato  
Festa_Near infrared spectroscopy_2023.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1713779
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact