Purpose: The aim of this study was to evaluate the potential of 3D exoscope (EX) in selected ear procedures assessing if this new technology could be an improvement in the field of ear surgery. Methods: A case series of consecutive patients surgically treated with a post-auricular approach using EX was retrospectively compared with a similar previous series treated with operating microscope (OM). Patient demographics, indications for surgery, procedure type, complications, operating room setting time (ORst), operative time, adequacy of visualization, image quality, ergonomics aspects, instrument usability, and technique as a teaching tool were investigated. Thirteen patients were included in each group. Surgical procedures in EX group were nine tympanoplasties with mastoidectomy, 1 mastoidectomy for acute complicated mastoiditis, 1 revision miringoplasty, and 2 cochlear implants. Same types of procedures were enrolled in OM group. Results: No statistically significant difference was found between the two groups concerning ORst and operative time. In EX group, one complication occurred--a middle cranial fossa cerebrospinal fluid leak. Advantages of EX were lightness, maneuverability and compactness, less need of endoscopy during surgery, and teaching potential. Limits were a need of a large surgical corridor and the bright structures rendering in high magnification. Conclusion: EX resulted safe and efficient in treating diseases of the middle ear in post-auricular approaches. To date, EX advantages are not enough to abandon the OM, and it can be considered as an additional, innovative tool to be added to ear surgical equipment.

Introducing the high-definition 3D exoscope in ear surgery: preliminary analysis of advantages and limits compared with operative microscope / Colombo, Giovanni; Ferreli, Fabio; Di Bari, Matteo; Cugini, Giovanni; Miceli, Stefano; De Virgilio, Armando; Spriano, Giuseppe; Poletti, Arturo. - In: EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY. - ISSN 0937-4477. - 278:11(2021), pp. 4217-4223. [10.1007/S00405-020-06510-W]

Introducing the high-definition 3D exoscope in ear surgery: preliminary analysis of advantages and limits compared with operative microscope

De Virgilio, Armando;
2021

Abstract

Purpose: The aim of this study was to evaluate the potential of 3D exoscope (EX) in selected ear procedures assessing if this new technology could be an improvement in the field of ear surgery. Methods: A case series of consecutive patients surgically treated with a post-auricular approach using EX was retrospectively compared with a similar previous series treated with operating microscope (OM). Patient demographics, indications for surgery, procedure type, complications, operating room setting time (ORst), operative time, adequacy of visualization, image quality, ergonomics aspects, instrument usability, and technique as a teaching tool were investigated. Thirteen patients were included in each group. Surgical procedures in EX group were nine tympanoplasties with mastoidectomy, 1 mastoidectomy for acute complicated mastoiditis, 1 revision miringoplasty, and 2 cochlear implants. Same types of procedures were enrolled in OM group. Results: No statistically significant difference was found between the two groups concerning ORst and operative time. In EX group, one complication occurred--a middle cranial fossa cerebrospinal fluid leak. Advantages of EX were lightness, maneuverability and compactness, less need of endoscopy during surgery, and teaching potential. Limits were a need of a large surgical corridor and the bright structures rendering in high magnification. Conclusion: EX resulted safe and efficient in treating diseases of the middle ear in post-auricular approaches. To date, EX advantages are not enough to abandon the OM, and it can be considered as an additional, innovative tool to be added to ear surgical equipment.
2021
cochlear implantation; exoscope; microscopy; otologic surgical procedures; tympanoplasty
01 Pubblicazione su rivista::01a Articolo in rivista
Introducing the high-definition 3D exoscope in ear surgery: preliminary analysis of advantages and limits compared with operative microscope / Colombo, Giovanni; Ferreli, Fabio; Di Bari, Matteo; Cugini, Giovanni; Miceli, Stefano; De Virgilio, Armando; Spriano, Giuseppe; Poletti, Arturo. - In: EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY. - ISSN 0937-4477. - 278:11(2021), pp. 4217-4223. [10.1007/S00405-020-06510-W]
File allegati a questo prodotto
File Dimensione Formato  
Colombo_Introducing the_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 863.79 kB
Formato Adobe PDF
863.79 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1713368
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 33
social impact