Objectives: To define the accuracy of autofluorescence-based (AF) and chemiluminescence-based (CL) systems in the diagnosis of oral dysplastic and malignant lesions in addition to the Conventional Oral Examination (COE). Materials and methods: The study was performed according to the PRISMA-DTA guidelines. Results: A total of 2631 oral cavity lesions (AF, n = 2076; CL, n = 555) from 26 studies (AF = 17; CL = 9) was used for calculation of diagnostic accuracy parameters. The overall pooled sensitivity and specificity of the AF were 81.3% (95% CI: 74.3% - 87.5%) and 52.1% (95% CI: 36.9% - 67.1%), respectively. Cumulative diagnostic odds ratio (DOR) was 5.44 (95% CI: 2.29 - 10.56) with a significant heterogeneity between studies (I2 = 80.7%, 95% CI: 70.0% - 86.7%; p < .05). The overall pooled sensitivity and specificity for the CL were 84.9% (95% CI: 66.7% - 96.7%) and 51.8% (95% CI: 37.3% - 65.9%), respectively. The overall pooled DOR was 8.59 (95% CI: 2.11 - 22.38) with a significant heterogeneity between studies (I2 = 65.4%, 95% CI: 29.6% - 83.0%; p < .05). Conclusions: AF and CL present a high sensitivity in the diagnosis of dysplastic and malignant oral cavity lesions, demonstrating that diagnostic biopsies may be avoided in case of a negative test result. Both tests have a low specificity, and the reduction of the false positive rate compared to the COE alone remains poor.

Accuracy of autofluorescence and chemiluminescence in the diagnosis of oral dysplasia and carcinoma: a systematic review and meta-analysis / Moffa, Antonio; Giorgi, Lucrezia; Costantino, Andrea; De Benedetto, Luigi; Cassano, Michele; Spriano, Giuseppe; Mercante, Giuseppe; De Virgilio, Armando; Casale, Manuele. - In: ORAL ONCOLOGY. - ISSN 1368-8375. - 121:(2021), pp. 1-9. [10.1016/J.ORALONCOLOGY.2021.105482]

Accuracy of autofluorescence and chemiluminescence in the diagnosis of oral dysplasia and carcinoma: a systematic review and meta-analysis

De Virgilio, Armando
Penultimo
;
2021

Abstract

Objectives: To define the accuracy of autofluorescence-based (AF) and chemiluminescence-based (CL) systems in the diagnosis of oral dysplastic and malignant lesions in addition to the Conventional Oral Examination (COE). Materials and methods: The study was performed according to the PRISMA-DTA guidelines. Results: A total of 2631 oral cavity lesions (AF, n = 2076; CL, n = 555) from 26 studies (AF = 17; CL = 9) was used for calculation of diagnostic accuracy parameters. The overall pooled sensitivity and specificity of the AF were 81.3% (95% CI: 74.3% - 87.5%) and 52.1% (95% CI: 36.9% - 67.1%), respectively. Cumulative diagnostic odds ratio (DOR) was 5.44 (95% CI: 2.29 - 10.56) with a significant heterogeneity between studies (I2 = 80.7%, 95% CI: 70.0% - 86.7%; p < .05). The overall pooled sensitivity and specificity for the CL were 84.9% (95% CI: 66.7% - 96.7%) and 51.8% (95% CI: 37.3% - 65.9%), respectively. The overall pooled DOR was 8.59 (95% CI: 2.11 - 22.38) with a significant heterogeneity between studies (I2 = 65.4%, 95% CI: 29.6% - 83.0%; p < .05). Conclusions: AF and CL present a high sensitivity in the diagnosis of dysplastic and malignant oral cavity lesions, demonstrating that diagnostic biopsies may be avoided in case of a negative test result. Both tests have a low specificity, and the reduction of the false positive rate compared to the COE alone remains poor.
2021
cancer; head and neck cancer; oral cavity; screening; squamous cell carcinoma
01 Pubblicazione su rivista::01a Articolo in rivista
Accuracy of autofluorescence and chemiluminescence in the diagnosis of oral dysplasia and carcinoma: a systematic review and meta-analysis / Moffa, Antonio; Giorgi, Lucrezia; Costantino, Andrea; De Benedetto, Luigi; Cassano, Michele; Spriano, Giuseppe; Mercante, Giuseppe; De Virgilio, Armando; Casale, Manuele. - In: ORAL ONCOLOGY. - ISSN 1368-8375. - 121:(2021), pp. 1-9. [10.1016/J.ORALONCOLOGY.2021.105482]
File allegati a questo prodotto
File Dimensione Formato  
Moffa_Accuracy of autofluorescence_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.38 MB
Formato Adobe PDF
2.38 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1713354
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact