Purpose: To describe a new surgical technique involving the use of a human amniotic membrane (hAM) epiretinal patch to treat a primary macular hole retinal detachment (MHRD) in a highly myopic patient.Methods: A 60 years old highly myopic man was referred to our clinic with a diagnosis of MHRD in his right eye. The patient was pseudophakic, with a visual acuity of counting fingers at the baseline evaluation. Pars plana vitrectomy was performed, a small retinotomy was created at the inner margin of the staphyloma, and membrane blue dual was used to obtain an adequate peeling of the inner limiting membrane. Then, a 1.5 mm diameter circular hAM patch was obtained and positioned over the macular hole with the chorion layer settled over the retina. After a complete fluid-air exchange, 20% sulfur hexafluoride gas was used as endotamponade, and the patient was asked to remain face down for three days.Results: Four weeks after surgery, optical coherence tomography (OCT) scan showed the hAM patch, visualized as a distinct hyperreflective layer well integrated with the retina. Nine months after surgery, the macular hole was closed, the retina reattached, the hAM patch was adherent to the retina, and the patient presented a best-corrected visual acuity improved to 0.7 logMar. No postoperative adverse events were registered during the follow-up.Conclusions: Epiretinal hAM implant could represent a novel surgical technique, feasible and easier compared to other current techniques used to treat MHRD in highly myopic patients.

Epiretinal implant of human amniotic membrane to treat highly myopic macular hole retinal detachments: a novel surgical technique / Iannetta, Danilo; Chhablani, Jay; Valsecchi, Nicola; Mesiani, Maria; de Smet, Marc D.; Fontana, Luigi. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 34:1(2024), pp. 304-309. [10.1177/11206721231206717]

Epiretinal implant of human amniotic membrane to treat highly myopic macular hole retinal detachments: a novel surgical technique

Iannetta, Danilo
Primo
;
2024

Abstract

Purpose: To describe a new surgical technique involving the use of a human amniotic membrane (hAM) epiretinal patch to treat a primary macular hole retinal detachment (MHRD) in a highly myopic patient.Methods: A 60 years old highly myopic man was referred to our clinic with a diagnosis of MHRD in his right eye. The patient was pseudophakic, with a visual acuity of counting fingers at the baseline evaluation. Pars plana vitrectomy was performed, a small retinotomy was created at the inner margin of the staphyloma, and membrane blue dual was used to obtain an adequate peeling of the inner limiting membrane. Then, a 1.5 mm diameter circular hAM patch was obtained and positioned over the macular hole with the chorion layer settled over the retina. After a complete fluid-air exchange, 20% sulfur hexafluoride gas was used as endotamponade, and the patient was asked to remain face down for three days.Results: Four weeks after surgery, optical coherence tomography (OCT) scan showed the hAM patch, visualized as a distinct hyperreflective layer well integrated with the retina. Nine months after surgery, the macular hole was closed, the retina reattached, the hAM patch was adherent to the retina, and the patient presented a best-corrected visual acuity improved to 0.7 logMar. No postoperative adverse events were registered during the follow-up.Conclusions: Epiretinal hAM implant could represent a novel surgical technique, feasible and easier compared to other current techniques used to treat MHRD in highly myopic patients.
2024
amniotic membrane implant; large macular hole; macular detachment; macular holes; myopia; vitreous surgery
01 Pubblicazione su rivista::01a Articolo in rivista
Epiretinal implant of human amniotic membrane to treat highly myopic macular hole retinal detachments: a novel surgical technique / Iannetta, Danilo; Chhablani, Jay; Valsecchi, Nicola; Mesiani, Maria; de Smet, Marc D.; Fontana, Luigi. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 34:1(2024), pp. 304-309. [10.1177/11206721231206717]
File allegati a questo prodotto
File Dimensione Formato  
Iannetta_Epiretinal implant_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.56 MB
Formato Adobe PDF
4.56 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1710941
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact