The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993–2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.
Prevalence of peri-implant mucositis, peri-implantitis and associated risk indicators of implants with and without Laser-Microgrooved collar surface: A long-term (≥20 Years) retrospective study / Guarnieri, R.; Reda, R.; Di Nardo, D.; Pagnoni, F.; Zanza, A.; Testarelli, L.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 14:4(2024). [10.3390/jpm14040342]
Prevalence of peri-implant mucositis, peri-implantitis and associated risk indicators of implants with and without Laser-Microgrooved collar surface: A long-term (≥20 Years) retrospective study
Guarnieri R.Primo
Conceptualization
;Reda R.
Secondo
Formal Analysis
;Di Nardo D.Writing – Original Draft Preparation
;Zanza A.Penultimo
Writing – Review & Editing
;Testarelli L.Ultimo
Supervision
2024
Abstract
The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993–2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.File | Dimensione | Formato | |
---|---|---|---|
Guarnieri_Prevalence-of-Peri-Implant_2024.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
2.61 MB
Formato
Adobe PDF
|
2.61 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.