The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993–2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.

Prevalence of Peri-Implant Mucositis, Peri-Implantitis and Associated Risk Indicators of Implants with and without Laser-Microgrooved Collar Surface: A Long-Term (≥20 Years) Retrospective Study / Guarnieri, R.; Reda, R.; Di Nardo, D.; Pagnoni, F.; Zanza, A.; Testarelli, L.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 14:4(2024). [10.3390/jpm14040342]

Prevalence of Peri-Implant Mucositis, Peri-Implantitis and Associated Risk Indicators of Implants with and without Laser-Microgrooved Collar Surface: A Long-Term (≥20 Years) Retrospective Study

Guarnieri R.
Primo
Conceptualization
;
Reda R.
Secondo
Formal Analysis
;
Di Nardo D.
Writing – Original Draft Preparation
;
Zanza A.
Penultimo
Writing – Review & Editing
;
Testarelli L.
Ultimo
Supervision
2024

Abstract

The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993–2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.
2024
implant neck; implants; laser-microgrooved collar surface; peri-implant mucositis; peri-implantitis
01 Pubblicazione su rivista::01a Articolo in rivista
Prevalence of Peri-Implant Mucositis, Peri-Implantitis and Associated Risk Indicators of Implants with and without Laser-Microgrooved Collar Surface: A Long-Term (≥20 Years) Retrospective Study / Guarnieri, R.; Reda, R.; Di Nardo, D.; Pagnoni, F.; Zanza, A.; Testarelli, L.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 14:4(2024). [10.3390/jpm14040342]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1709583
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact