Following Phase 2 of the upgrade of the ESRF in which the storage ring was replaced by a new low-emittance ring along with many other facility upgrades, the status of ID22, the high-resolution powder-diffraction beamline, is described. The beamline has an in-vacuum undulator as source providing X-rays in the range 6-75 keV. ID22's principle characteristics include very high angular resolution as a result of the highly collimated and monochromatic beam, coupled with a 13-channel Si 111 multi-analyser stage between the sample and a Dectris Eiger2 X 2M-W CdTe pixel detector. The detector's axial resolution allows recorded 2 theta values to be automatically corrected for the effects of axial divergence, resulting in narrower and more-symmetric peaks compared with the previous fixed-axial-slit arrangement. The axial acceptance can also be increased with increasing diffraction angle, thus simultaneously improving the statistical quality of high-angle data. A complementary Perkin Elmer XRD1611 medical-imaging detector is available for faster, lower-resolution data, often used at photon energies of 60-70 keV for pair-distribution function analysis, although this is also possible in high-resolution mode by scanning up to 120 degrees 2 theta at 35 keV. There are various sample environments, allowing sample temperatures from 4 K to 1600 degrees C, a capillary cell for non-corrosive gas atmospheres in the range 0-100 bar, and a sample-changing robot that can accommodate 75 capillary samples compatible with the temperature range 80 K to 950 degrees C.

ID22 – the high-resolution powder-diffraction beamline at ESRF / Fitch, Andrew; Dejoie, Catherine; Covacci, Ezio; Confalonieri, Giorgia; Grendal, Ola; Claustre, Laurent; Guillou, Perceval; Kieffer, Jérôme; de Nolf, Wout; Petitdemange, Sébastien; Ruat, Marie; Watier, Yves. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 1600-5775. - 30:5(2023), pp. 1003-1012. [10.1107/s1600577523004915]

ID22 – the high-resolution powder-diffraction beamline at ESRF

Confalonieri, Giorgia;
2023

Abstract

Following Phase 2 of the upgrade of the ESRF in which the storage ring was replaced by a new low-emittance ring along with many other facility upgrades, the status of ID22, the high-resolution powder-diffraction beamline, is described. The beamline has an in-vacuum undulator as source providing X-rays in the range 6-75 keV. ID22's principle characteristics include very high angular resolution as a result of the highly collimated and monochromatic beam, coupled with a 13-channel Si 111 multi-analyser stage between the sample and a Dectris Eiger2 X 2M-W CdTe pixel detector. The detector's axial resolution allows recorded 2 theta values to be automatically corrected for the effects of axial divergence, resulting in narrower and more-symmetric peaks compared with the previous fixed-axial-slit arrangement. The axial acceptance can also be increased with increasing diffraction angle, thus simultaneously improving the statistical quality of high-angle data. A complementary Perkin Elmer XRD1611 medical-imaging detector is available for faster, lower-resolution data, often used at photon energies of 60-70 keV for pair-distribution function analysis, although this is also possible in high-resolution mode by scanning up to 120 degrees 2 theta at 35 keV. There are various sample environments, allowing sample temperatures from 4 K to 1600 degrees C, a capillary cell for non-corrosive gas atmospheres in the range 0-100 bar, and a sample-changing robot that can accommodate 75 capillary samples compatible with the temperature range 80 K to 950 degrees C.
2023
ESRF; PDF analysis; high resolution; powder X-ray diffraction
01 Pubblicazione su rivista::01a Articolo in rivista
ID22 – the high-resolution powder-diffraction beamline at ESRF / Fitch, Andrew; Dejoie, Catherine; Covacci, Ezio; Confalonieri, Giorgia; Grendal, Ola; Claustre, Laurent; Guillou, Perceval; Kieffer, Jérôme; de Nolf, Wout; Petitdemange, Sébastien; Ruat, Marie; Watier, Yves. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 1600-5775. - 30:5(2023), pp. 1003-1012. [10.1107/s1600577523004915]
File allegati a questo prodotto
File Dimensione Formato  
Fitch_ID22_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.68 MB
Formato Adobe PDF
1.68 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1707199
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 50
social impact