The Einstein Telescope (ET) is a third-generation gravitational wave detector that includes a room temperature high-frequency (ET-HF) and a cryogenic low-frequency laser interferometer (ET-LF). The cryogenic ET-LF is crucial for exploiting the full scientific potential of the ET. We present a new baseline design for the cryogenic payload that is thermally and mechanically consistent and compatible with the design sensitivity curve of the ET. The design includes two options for the heat extraction from the marionette, based on a monocrystalline high-conductivity marionette suspension fiber and a thin-wall titanium tube filled with static He-II. Following a detailed description of the design options and the suspension thermal noise (STN) modeling, we present the sensitivity curves of the two baseline designs, discuss the influence of various design parameters on the sensitivity of ET-LF, and conclude with an outlook to future R&D activities.

Cryogenic payloads for the Einstein telescope. Baseline design with heat extraction, suspension thermal noise modeling, and sensitivity analyses / Koroveshi, Xhesika; Busch, Lennard; Majorana, Ettore; Puppo, Paola; Rapagnani, Piero; Ricci, Fulvio; Ruggi, Paolo; Grohmann, Steffen. - In: PHYSICAL REVIEW D. - ISSN 2470-0029. - 108:(2023), pp. 1-21. [10.1103/PhysRevD.108.123009]

Cryogenic payloads for the Einstein telescope. Baseline design with heat extraction, suspension thermal noise modeling, and sensitivity analyses

Ettore Majorana
Writing – Review & Editing
;
Piero Rapagnani
Writing – Original Draft Preparation
;
2023

Abstract

The Einstein Telescope (ET) is a third-generation gravitational wave detector that includes a room temperature high-frequency (ET-HF) and a cryogenic low-frequency laser interferometer (ET-LF). The cryogenic ET-LF is crucial for exploiting the full scientific potential of the ET. We present a new baseline design for the cryogenic payload that is thermally and mechanically consistent and compatible with the design sensitivity curve of the ET. The design includes two options for the heat extraction from the marionette, based on a monocrystalline high-conductivity marionette suspension fiber and a thin-wall titanium tube filled with static He-II. Following a detailed description of the design options and the suspension thermal noise (STN) modeling, we present the sensitivity curves of the two baseline designs, discuss the influence of various design parameters on the sensitivity of ET-LF, and conclude with an outlook to future R&D activities.
2023
gravitational waves; cryogenics; Einstein telescope
01 Pubblicazione su rivista::01a Articolo in rivista
Cryogenic payloads for the Einstein telescope. Baseline design with heat extraction, suspension thermal noise modeling, and sensitivity analyses / Koroveshi, Xhesika; Busch, Lennard; Majorana, Ettore; Puppo, Paola; Rapagnani, Piero; Ricci, Fulvio; Ruggi, Paolo; Grohmann, Steffen. - In: PHYSICAL REVIEW D. - ISSN 2470-0029. - 108:(2023), pp. 1-21. [10.1103/PhysRevD.108.123009]
File allegati a questo prodotto
File Dimensione Formato  
Koroveshi_Cryogenic-payloads_2023.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.15 MB
Formato Adobe PDF
4.15 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1705766
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact