In this paper, the results of a measurement campaign of UV solar radiation, carried out with different broadband radiometers and a precision spectrometer, are shown, described and analyzed. The parameters measured by the considered devices are relevant for the evaluation of human exposure to UV solar radiation. From the obtained results, it was possible to characterize the deviations between the measurements obtained by the broadband radiometers and those obtained by the precision spectrometer. The measurement results were analyzed globally and for each individual radiometer. Through the analysis, it was possible to identify a procedure for a sort of calibration of the broadband radiometers, based on the determination of corrective factors, with which to adjust the results of the measurements in order to obtain very precise estimates of the amount of the exposure.
Broadband radiometers for the assessment of workers' exposure to UV radiation: comparison of measurement results obtained with different devices / Bisegna, Fabio; Burattini, Chiara; Pompei, Laura; Rocca, Michele; Leccese, Francesco; Salvadori, Giacomo; Borra, Masimo; Militello, Andrea. - (2023), pp. 1-6. (Intervento presentato al convegno 2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe, EEEIC / I and CPS Europe 2023 tenutosi a Madrid; Spain) [10.1109/eeeic/icpseurope57605.2023.10194678].
Broadband radiometers for the assessment of workers' exposure to UV radiation: comparison of measurement results obtained with different devices
Bisegna, Fabio;Burattini, Chiara;Pompei, Laura;Rocca, Michele;
2023
Abstract
In this paper, the results of a measurement campaign of UV solar radiation, carried out with different broadband radiometers and a precision spectrometer, are shown, described and analyzed. The parameters measured by the considered devices are relevant for the evaluation of human exposure to UV solar radiation. From the obtained results, it was possible to characterize the deviations between the measurements obtained by the broadband radiometers and those obtained by the precision spectrometer. The measurement results were analyzed globally and for each individual radiometer. Through the analysis, it was possible to identify a procedure for a sort of calibration of the broadband radiometers, based on the determination of corrective factors, with which to adjust the results of the measurements in order to obtain very precise estimates of the amount of the exposure.File | Dimensione | Formato | |
---|---|---|---|
Bisegna_Broadband radiometers_2023.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.2 MB
Formato
Adobe PDF
|
2.2 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.