Purpose Continuous Glucose Monitoring (CGM) is a key tool for insulin-treated people with diabetes (PwD). CGM devices include both real-time CGM (rtCGM) and intermittently scanned CGM (isCGM), which are associated with an improvement of glucose control and less hypoglycemia in clinical trials of people with type 1 and type 2 diabetes. 1234567890();,: 1234567890();,: Methods This is an expert position to update a previous algorithm on the most suitable choice of CGM for insulin-treated PwD in light of the recent evidence and clinical practice. Results We identified six different clinical scenarios, including type 1 diabetes, type 2 diabetes, pregnancy on intensive insulin therapy, regular physical exercise, new onset of diabetes, and frailty. The use of rtCGM or isCGM is suggested, on the basis of the predominant clinical issue, as suboptimal glucose control or disabling hypoglycemia, regardless of baseline HbA1c or individualized HbA1c target. Conclusion The present algorithm may help to select the best CGM device based on patients’ clinical characteristics, needs and clinical context, offering a further opportunity of a “tailored” therapy for people with insulin-treated diabetes.

An updated algorithm for an effective choice of continuous glucose monitoring for people with insulin-treated diabetes / Ida Maiorino, Maria; Buzzetti, Raffaella; Irace, Concetta; Laviola, Luigi; Napoli, Nicola; Pitocco, Dario; Esposito, Katherine; CGM working group, Live. - In: ENDOCRINE. - ISSN 1559-0100. - (2023).

An updated algorithm for an effective choice of continuous glucose monitoring for people with insulin-treated diabetes

Raffaella Buzzetti;
2023

Abstract

Purpose Continuous Glucose Monitoring (CGM) is a key tool for insulin-treated people with diabetes (PwD). CGM devices include both real-time CGM (rtCGM) and intermittently scanned CGM (isCGM), which are associated with an improvement of glucose control and less hypoglycemia in clinical trials of people with type 1 and type 2 diabetes. 1234567890();,: 1234567890();,: Methods This is an expert position to update a previous algorithm on the most suitable choice of CGM for insulin-treated PwD in light of the recent evidence and clinical practice. Results We identified six different clinical scenarios, including type 1 diabetes, type 2 diabetes, pregnancy on intensive insulin therapy, regular physical exercise, new onset of diabetes, and frailty. The use of rtCGM or isCGM is suggested, on the basis of the predominant clinical issue, as suboptimal glucose control or disabling hypoglycemia, regardless of baseline HbA1c or individualized HbA1c target. Conclusion The present algorithm may help to select the best CGM device based on patients’ clinical characteristics, needs and clinical context, offering a further opportunity of a “tailored” therapy for people with insulin-treated diabetes.
2023
Continuous glucose monitoring ● rtCGM ● isCGM ● Algorithm ● Insulin-treated diabetes ● Hypoglycemia
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
An updated algorithm for an effective choice of continuous glucose monitoring for people with insulin-treated diabetes / Ida Maiorino, Maria; Buzzetti, Raffaella; Irace, Concetta; Laviola, Luigi; Napoli, Nicola; Pitocco, Dario; Esposito, Katherine; CGM working group, Live. - In: ENDOCRINE. - ISSN 1559-0100. - (2023).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1702381
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact