Indirect lightning causes power outages along over-head distribution lines. The installation of surge arresters (SAs) at the line towers/poles effectively reduces lightning-induced overvoltages. Among the types of SAs used in practice, non-gapped line arresters (NGLAs) have been mainly used in the past for a long time, while externally gapped line arresters (EGLAs) are being used in recent practice to overcome the disadvantages of NGLAs. This analysis focuses on the performance of these SAs in terms of flashover mitigation on a real medium voltage distribution line. Critical lightning parameters, including lightning current magnitude, and tower footing resistance, are considered. The primary objective of the analysis is to identify the SA that offers superior lightning performance. This evaluation is crucial for optimizing the prospective location of the arresters. By comparing the lightning performance of different SAs, the study aims to determine the most effective option for mitigating lightning-induced surges.

Selection of viable distribution line surge arrester for prospective optimal protection / Ravichandran, N.; Andreotti, A.; Pasquale, A. D.; Pagano, M.; Proto, D.; Stracqualursi, E.; Araneo, R.; D'Orazio, L.. - (2023), pp. 1-6. (Intervento presentato al convegno 115th AEIT International Annual Conference, AEIT 2023 tenutosi a Rome; Italy) [10.23919/AEIT60520.2023.10330403].

Selection of viable distribution line surge arrester for prospective optimal protection

Stracqualursi E.;Araneo R.;
2023

Abstract

Indirect lightning causes power outages along over-head distribution lines. The installation of surge arresters (SAs) at the line towers/poles effectively reduces lightning-induced overvoltages. Among the types of SAs used in practice, non-gapped line arresters (NGLAs) have been mainly used in the past for a long time, while externally gapped line arresters (EGLAs) are being used in recent practice to overcome the disadvantages of NGLAs. This analysis focuses on the performance of these SAs in terms of flashover mitigation on a real medium voltage distribution line. Critical lightning parameters, including lightning current magnitude, and tower footing resistance, are considered. The primary objective of the analysis is to identify the SA that offers superior lightning performance. This evaluation is crucial for optimizing the prospective location of the arresters. By comparing the lightning performance of different SAs, the study aims to determine the most effective option for mitigating lightning-induced surges.
2023
115th AEIT International Annual Conference, AEIT 2023
distribution lines; flashover; lightning overvoltage; line surge arrester
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Selection of viable distribution line surge arrester for prospective optimal protection / Ravichandran, N.; Andreotti, A.; Pasquale, A. D.; Pagano, M.; Proto, D.; Stracqualursi, E.; Araneo, R.; D'Orazio, L.. - (2023), pp. 1-6. (Intervento presentato al convegno 115th AEIT International Annual Conference, AEIT 2023 tenutosi a Rome; Italy) [10.23919/AEIT60520.2023.10330403].
File allegati a questo prodotto
File Dimensione Formato  
Ravichandran_Selection_2023.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 491.25 kB
Formato Adobe PDF
491.25 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1701925
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact