Due to their advantages in ensuring low harmonic distortion and high power factors, single-phase Pulse-Width Modulated (PWM) rectifiers are widely employed in several industrial applications. Generally, the conventional control loop of a single-phase PWM rectifier uses both voltage and current sensors. Hence, in case of sensor fault, the performance and the availability of the converter can be seriously compromised. Therefore, diagnosis approaches and fault-tolerant control (FTC) strategies are mandatory to monitor these systems. Accordingly, this paper introduces a novel multiple-sensor FTC scheme for a single-phase PWM rectifier. The proposed fault diagnosis approach relies on joining several Generalized Proportional Integral (GPI) and Model Reference Adaptive System (MRAS) observers with a residual generation technique to detect and isolate sensor faults in a simple and reliable manner. While conventional sensor FTC methods dedicated to PWM rectifiers can only deal with single faults, the suggested approach guarantees a very good effectiveness level of sensor fault detection, isolation (FDI) and FTC of multiple-sensor fault occurrence scenarios. Consequently, the single-phase PWM rectifier can work with only the survivable single sensor with the guarantee of very good performance as in healthy operation mode. The effectiveness of the proposed sensor FDI approach and its control reconfiguration performance are demonstrated through both extensive simulation and experimental results.

A Multiple-Sensor Fault-Tolerant Control of a Single-Phase Pulse-Width Modulated Rectifier Based on MRAS and GPI Observers / Dardouri, Meriem; Salman, Muhammad; Khojet El Khil, S.; Boccaletti, Chiara; Khaled, Jelassi. - In: ELECTRONICS. - ISSN 2079-9292. - 13 (2024):3(2024), pp. 1-23. [10.3390/electronics13030502]

A Multiple-Sensor Fault-Tolerant Control of a Single-Phase Pulse-Width Modulated Rectifier Based on MRAS and GPI Observers

MUHAMMAD SALMAN
Secondo
Software
;
Chiara Boccaletti
Formal Analysis
;
2024

Abstract

Due to their advantages in ensuring low harmonic distortion and high power factors, single-phase Pulse-Width Modulated (PWM) rectifiers are widely employed in several industrial applications. Generally, the conventional control loop of a single-phase PWM rectifier uses both voltage and current sensors. Hence, in case of sensor fault, the performance and the availability of the converter can be seriously compromised. Therefore, diagnosis approaches and fault-tolerant control (FTC) strategies are mandatory to monitor these systems. Accordingly, this paper introduces a novel multiple-sensor FTC scheme for a single-phase PWM rectifier. The proposed fault diagnosis approach relies on joining several Generalized Proportional Integral (GPI) and Model Reference Adaptive System (MRAS) observers with a residual generation technique to detect and isolate sensor faults in a simple and reliable manner. While conventional sensor FTC methods dedicated to PWM rectifiers can only deal with single faults, the suggested approach guarantees a very good effectiveness level of sensor fault detection, isolation (FDI) and FTC of multiple-sensor fault occurrence scenarios. Consequently, the single-phase PWM rectifier can work with only the survivable single sensor with the guarantee of very good performance as in healthy operation mode. The effectiveness of the proposed sensor FDI approach and its control reconfiguration performance are demonstrated through both extensive simulation and experimental results.
2024
single-phase pulse-width modulated rectifier; sensor fault detection; fault-tolerant control; observers; GPIO; MRAS
01 Pubblicazione su rivista::01a Articolo in rivista
A Multiple-Sensor Fault-Tolerant Control of a Single-Phase Pulse-Width Modulated Rectifier Based on MRAS and GPI Observers / Dardouri, Meriem; Salman, Muhammad; Khojet El Khil, S.; Boccaletti, Chiara; Khaled, Jelassi. - In: ELECTRONICS. - ISSN 2079-9292. - 13 (2024):3(2024), pp. 1-23. [10.3390/electronics13030502]
File allegati a questo prodotto
File Dimensione Formato  
Dardouri_A-Multiple-Sensor_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1700789
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact