Seventy-one cases that had resulted borderline for HER-2 protein expression at conventional immunohistochemical assay (2+) were assessed for HER-2 gene amplification by real-time PCR and by FISH in accordance with the manufacturer's recommendations (gene amplification with ratio >or=2 in both methods). Thirty-three out of 71 cases (47%) resulted amplified at real-time PCR analysis, whereas 15 cases resulted positive at FISH (21%). Apparently, PCR was more sensitive than FISH in HER-2 determination, only 10 cases resulting amplified in both tests. When the mean ratio value obtained in all PCR experiments was adopted as threshold in determining HER-2 gene amplification, the apparent sensitivity of PCR was reduced but correlation between PCR and FISH results was dramatically increased. Furthermore, when the mean PCR ratio value observed in the FISH-positive group was chosen as threshold, the best agreement between PCR and FISH results was achieved. Therefore, we found that the proposed threshold ratio value of >or=2 is not accurate in separating HER-2 amplified and non-amplified cases. We suggest that the threshold ratio value in PCR tests should be determined in each laboratory using FISH controlled cases. Finally, above certain in-lab generated threshold values, PCR might be proposed as a highly predictive positive test in HER-2 assessment.

Borderline HER-2 breast cancer cases: histochemical versus real-time PCR analysis and impact of different cut-off values / Monego, G; Arena, V; Maggiano, N; Costarelli, L; Crescenzi, A; Zelano, G; Amini, M; Capelli, A; Carbone, A. - In: SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION. - ISSN 0036-5513. - 67:4(2007), pp. 402-412. [10.1080/00365510601128934]

Borderline HER-2 breast cancer cases: histochemical versus real-time PCR analysis and impact of different cut-off values

Crescenzi A;
2007

Abstract

Seventy-one cases that had resulted borderline for HER-2 protein expression at conventional immunohistochemical assay (2+) were assessed for HER-2 gene amplification by real-time PCR and by FISH in accordance with the manufacturer's recommendations (gene amplification with ratio >or=2 in both methods). Thirty-three out of 71 cases (47%) resulted amplified at real-time PCR analysis, whereas 15 cases resulted positive at FISH (21%). Apparently, PCR was more sensitive than FISH in HER-2 determination, only 10 cases resulting amplified in both tests. When the mean ratio value obtained in all PCR experiments was adopted as threshold in determining HER-2 gene amplification, the apparent sensitivity of PCR was reduced but correlation between PCR and FISH results was dramatically increased. Furthermore, when the mean PCR ratio value observed in the FISH-positive group was chosen as threshold, the best agreement between PCR and FISH results was achieved. Therefore, we found that the proposed threshold ratio value of >or=2 is not accurate in separating HER-2 amplified and non-amplified cases. We suggest that the threshold ratio value in PCR tests should be determined in each laboratory using FISH controlled cases. Finally, above certain in-lab generated threshold values, PCR might be proposed as a highly predictive positive test in HER-2 assessment.
2007
breast neoplasms; Gene Expression Regulation, Neoplastic; Reverse Transcriptase Polymerase Chain Reaction/*methods
01 Pubblicazione su rivista::01a Articolo in rivista
Borderline HER-2 breast cancer cases: histochemical versus real-time PCR analysis and impact of different cut-off values / Monego, G; Arena, V; Maggiano, N; Costarelli, L; Crescenzi, A; Zelano, G; Amini, M; Capelli, A; Carbone, A. - In: SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION. - ISSN 0036-5513. - 67:4(2007), pp. 402-412. [10.1080/00365510601128934]
File allegati a questo prodotto
File Dimensione Formato  
HER2PAPER[1].pdf

solo gestori archivio

Note: Monego_Borderline HER-2_2007
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 268.93 kB
Formato Adobe PDF
268.93 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1700072
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact