Purpose: The sensitivity of cytology after fine needle aspiration (FNA-cytology) in detecting medullary thyroid carcinoma (MTC) is low. To overcome this problem, measuring calcitonin (CT) in washout fluid of FNA (FNA-CT) has been largely diffused and showed good performance. However, no evidence-based study exists comparing systematically the sensitivity of FNA-cytology and FNA-CT. This study aimed to systematically review the literature and collect data allowing a head-to-head comparison meta-analysis between FNA-cytology and FNA-CT in detecting MTC lesions. Methods: The online databases of PubMed/MEDLINE and Scopus were searched until June 2021. Original articles reporting the use of both FNA-cytology and FNA-CT in the same series of histologically proven MTC lesions were included They were extracted general features of each study, number of MTC lesions (nodule and neck lymph nodes), and true positive and false negatives of both FNA-cytology and FNA-CT. Results: Six studies were included. The sensitivity of FNA-cytology varied from 20% to 86% with a pooled value of 54% (95% CI 35–73%) and significant heterogeneity. The sensitivity of FNA-CT was higher than 95% in almost all studies with a pooled value of 98% (95% CI 96–100%) without heterogeneity. The sensitivity of FNA-CT was significantly higher than that of FNA-cytology. Conclusions: FNA-CT is significantly more sensitive than FNA-cytology in detecting MTC. Accordingly, FNA-CT represents the standard method to use in patients with suspicious MTC lesions, combined with cytology.

Head-to-head comparison of FNA cytology vs. calcitonin measurement in FNA washout fluids (FNA-CT) to diagnose medullary thyroid carcinoma. A systematic review and meta-analysis / Trimboli, P; Giannelli, J; Marques, B; Piccardo, A; Crescenzi, A; Deandrea, M.. - In: ENDOCRINE. - ISSN 1559-0100. - 75:1(2022), pp. 33-39. [10.1007/s12020-021-02892-x]

Head-to-head comparison of FNA cytology vs. calcitonin measurement in FNA washout fluids (FNA-CT) to diagnose medullary thyroid carcinoma. A systematic review and meta-analysis

Crescenzi, A;
2022

Abstract

Purpose: The sensitivity of cytology after fine needle aspiration (FNA-cytology) in detecting medullary thyroid carcinoma (MTC) is low. To overcome this problem, measuring calcitonin (CT) in washout fluid of FNA (FNA-CT) has been largely diffused and showed good performance. However, no evidence-based study exists comparing systematically the sensitivity of FNA-cytology and FNA-CT. This study aimed to systematically review the literature and collect data allowing a head-to-head comparison meta-analysis between FNA-cytology and FNA-CT in detecting MTC lesions. Methods: The online databases of PubMed/MEDLINE and Scopus were searched until June 2021. Original articles reporting the use of both FNA-cytology and FNA-CT in the same series of histologically proven MTC lesions were included They were extracted general features of each study, number of MTC lesions (nodule and neck lymph nodes), and true positive and false negatives of both FNA-cytology and FNA-CT. Results: Six studies were included. The sensitivity of FNA-cytology varied from 20% to 86% with a pooled value of 54% (95% CI 35–73%) and significant heterogeneity. The sensitivity of FNA-CT was higher than 95% in almost all studies with a pooled value of 98% (95% CI 96–100%) without heterogeneity. The sensitivity of FNA-CT was significantly higher than that of FNA-cytology. Conclusions: FNA-CT is significantly more sensitive than FNA-cytology in detecting MTC. Accordingly, FNA-CT represents the standard method to use in patients with suspicious MTC lesions, combined with cytology.
2022
Calcitonin; Cytology; FNA; Medullary thyroid cancer; Meta-analysis; Washout; Biopsy; Fine-Needle; Calcitonin; Humans; Tomography; X-Ray Computed; Carcinoma; Neuroendocrine; Thyroid Neoplasms; Thyroid Nodule
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Head-to-head comparison of FNA cytology vs. calcitonin measurement in FNA washout fluids (FNA-CT) to diagnose medullary thyroid carcinoma. A systematic review and meta-analysis / Trimboli, P; Giannelli, J; Marques, B; Piccardo, A; Crescenzi, A; Deandrea, M.. - In: ENDOCRINE. - ISSN 1559-0100. - 75:1(2022), pp. 33-39. [10.1007/s12020-021-02892-x]
File allegati a questo prodotto
File Dimensione Formato  
12020_2021_Article_2892.pdf

accesso aperto

Note: Trimboli_Head-to-head comparison_2022
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1700008
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 19
social impact