Background: To determine the effect of a novel intracycle motion correction algorithm (MCA) on diagnostic accuracy of coronary computed tomographic angiography. Methods: Coronary artery phantom models were scanned at static and heart rate (HR) simulation of 60-100 beat/min and reconstructed with a conventional algorithm and MCA. Results: Among 144 coronary segments, improvements in image interpretability, quality, and diagnostic accuracy by MCA were observed for HRs of 80 and 100 (P<.05 for all), but not for HR of 60. Conclusion: Novel intracycle MCA demonstrates improved HR-dependent image interpretability, and quality and accuracy, particularly at higher HRs. (C) 2015 Elsevier Inc. All rights reserved.

Heart-rate dependent improvement in image quality and diagnostic accuracy of coronary computed tomographic angiography by novel intracycle motion correction algorithm / Cho, I; Elmore, K; Hartaigh, Bo; Schulman-Marcus, J; Granser, H; Valenti, V; Xiong, Gl; Carrascosa, Pm; Min, Jk. - In: CLINICAL IMAGING. - ISSN 0899-7071. - 39:3(2015), pp. 421-426. [10.1016/j.clinimag.2014.11.020]

Heart-rate dependent improvement in image quality and diagnostic accuracy of coronary computed tomographic angiography by novel intracycle motion correction algorithm

Valenti V;
2015

Abstract

Background: To determine the effect of a novel intracycle motion correction algorithm (MCA) on diagnostic accuracy of coronary computed tomographic angiography. Methods: Coronary artery phantom models were scanned at static and heart rate (HR) simulation of 60-100 beat/min and reconstructed with a conventional algorithm and MCA. Results: Among 144 coronary segments, improvements in image interpretability, quality, and diagnostic accuracy by MCA were observed for HRs of 80 and 100 (P<.05 for all), but not for HR of 60. Conclusion: Novel intracycle MCA demonstrates improved HR-dependent image interpretability, and quality and accuracy, particularly at higher HRs. (C) 2015 Elsevier Inc. All rights reserved.
2015
01 Pubblicazione su rivista::01a Articolo in rivista
Heart-rate dependent improvement in image quality and diagnostic accuracy of coronary computed tomographic angiography by novel intracycle motion correction algorithm / Cho, I; Elmore, K; Hartaigh, Bo; Schulman-Marcus, J; Granser, H; Valenti, V; Xiong, Gl; Carrascosa, Pm; Min, Jk. - In: CLINICAL IMAGING. - ISSN 0899-7071. - 39:3(2015), pp. 421-426. [10.1016/j.clinimag.2014.11.020]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1697264
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 19
social impact