We tested a new portable metabolic system, the Jaeger Oxycon Mobile (OM) at a range of running speeds. Six subjects carried out, in random order, two incremental tests on a treadmill, one of them using the OM, and the other using the Jaeger Oxycon Pro (OP). There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the OM. Production of CO2 (VCO2) tends to be overestimated by the OM, although the differences are not significant. Ventilation (VE) showed very similar values in both analyzers. Data of VO2 and RER were corrected with a regression equation which minimised the differences among the devices. The portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed systems. Key pointsPortable metabolic systems are frequently used to explore various physiological ventilatory variables in field tests.There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the Jaeger Oxycon Mobile (OM) portable metabolic systemProduction of CO2 (VCO2) tends to be overestimated by the OMData of VO2 and RER can be corrected with a regression equationThe portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed systems.

Validation of a new portable metabolic system during an incremental running test / Díaz, V; Benito, Pj; Peinado, Ab; Alvarez, M; Martín, C; Salvo, Vd; Pigozzi, F; Maffulli, Nicola; Calderón, F. J.. - In: JOURNAL OF SPORTS SCIENCE AND MEDICINE. - ISSN 1303-2968. - (2008), pp. 532-536.

Validation of a new portable metabolic system during an incremental running test

MAFFULLI, Nicola;
2008

Abstract

We tested a new portable metabolic system, the Jaeger Oxycon Mobile (OM) at a range of running speeds. Six subjects carried out, in random order, two incremental tests on a treadmill, one of them using the OM, and the other using the Jaeger Oxycon Pro (OP). There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the OM. Production of CO2 (VCO2) tends to be overestimated by the OM, although the differences are not significant. Ventilation (VE) showed very similar values in both analyzers. Data of VO2 and RER were corrected with a regression equation which minimised the differences among the devices. The portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed systems. Key pointsPortable metabolic systems are frequently used to explore various physiological ventilatory variables in field tests.There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the Jaeger Oxycon Mobile (OM) portable metabolic systemProduction of CO2 (VCO2) tends to be overestimated by the OMData of VO2 and RER can be corrected with a regression equationThe portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed systems.
2008
01 Pubblicazione su rivista::01a Articolo in rivista
Validation of a new portable metabolic system during an incremental running test / Díaz, V; Benito, Pj; Peinado, Ab; Alvarez, M; Martín, C; Salvo, Vd; Pigozzi, F; Maffulli, Nicola; Calderón, F. J.. - In: JOURNAL OF SPORTS SCIENCE AND MEDICINE. - ISSN 1303-2968. - (2008), pp. 532-536.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1695281
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 24
social impact