A shaking table experiment conducted on a multi-degrees-of-freedom frame structure equipped with a non-conventional tuned mass damper (TMD) is presented. The non-conventional TMD is characterized by a high mass ratio, without adding further structural masses, and is realized via inter-story isolation. The structure top story mass of a four-story steel frame structure is isolated and converted into tuned mass, connecting to the substructure with two high damping rubber bearings placed in series. Aspects related to the dynamic structural response as well as the seismic effectiveness assessment of a non-conventional TMD are addressed. Three structural configurations are tested: the reference four-story structure, the three-story intermediate structure, and the three-story structure equipped with a non-conventional TMD. The input motion conditions considered are: white noise, sine sweep, and natural earthquakes. Through experiments, structural identification is carried out and different dynamic behaviors emerge for the configurations tested. The nonlinear effects provoked on the structure by the adopted isolators are investigated, showing high dissipative capabilities in a wide range of amplitudes of the excitation. It is demonstrated that a non-conventional TMD is a smart control strategy useful for enhancing structural vibration mitigation.
Experimental Dynamic Response of a Multi-Story Frame Structure Equipped with Non-Conventional TMD Implemented via Inter-Story Isolation / Basili, M.; De Angelis, M. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 12:18(2022), pp. 1-22. [10.3390/app12189153]
Experimental Dynamic Response of a Multi-Story Frame Structure Equipped with Non-Conventional TMD Implemented via Inter-Story Isolation
De Angelis MSecondo
2022
Abstract
A shaking table experiment conducted on a multi-degrees-of-freedom frame structure equipped with a non-conventional tuned mass damper (TMD) is presented. The non-conventional TMD is characterized by a high mass ratio, without adding further structural masses, and is realized via inter-story isolation. The structure top story mass of a four-story steel frame structure is isolated and converted into tuned mass, connecting to the substructure with two high damping rubber bearings placed in series. Aspects related to the dynamic structural response as well as the seismic effectiveness assessment of a non-conventional TMD are addressed. Three structural configurations are tested: the reference four-story structure, the three-story intermediate structure, and the three-story structure equipped with a non-conventional TMD. The input motion conditions considered are: white noise, sine sweep, and natural earthquakes. Through experiments, structural identification is carried out and different dynamic behaviors emerge for the configurations tested. The nonlinear effects provoked on the structure by the adopted isolators are investigated, showing high dissipative capabilities in a wide range of amplitudes of the excitation. It is demonstrated that a non-conventional TMD is a smart control strategy useful for enhancing structural vibration mitigation.File | Dimensione | Formato | |
---|---|---|---|
Basili_Experimental_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
21.8 MB
Formato
Adobe PDF
|
21.8 MB | Adobe PDF | |
Basili_Experimental_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.26 MB
Formato
Adobe PDF
|
1.26 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.