In this work, functionally graded femoral prostheses (FGFPs) with different geometrical configurations are studied using three-dimensional finite element analysis. The FGFP consists of stainless steel-hydroxyapatite (SS 316L-HA) and titanium alloy-hydroxyapatite (Ti-HA) with various volume fraction gradient exponents n=0.0, 0.1, 0.5, and 1.0. This study is the first to consider an FGFP with a combination of different profiles and cross-sections in a non-bonded implant-bone interface. The results show that the strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP with different geometrical configurations, which correspond to a reduction in stress shielding and subsequently decrease bone resorption. Simultaneously, the interface stresses in the bone-implant contact region have limited variations for all combinations of profiles and cross-sections. Therefore, FGFP can be employed to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease stress shielding and interface stress. This condition results in an increase in the total lifespan of the hip replacement. © 2014 Elsevier Ltd.

Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations / Oshkour, A.A., Osman, N.A.A., Bayat, M., Afshar, R., Berto, F.. - In: MATERIALS & DESIGN. - ISSN 0264-1275. - 56:(2014), pp. 998-1008. [10.1016/j.matdes.2013.12.054]

Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations

Berto F.
2014

Abstract

In this work, functionally graded femoral prostheses (FGFPs) with different geometrical configurations are studied using three-dimensional finite element analysis. The FGFP consists of stainless steel-hydroxyapatite (SS 316L-HA) and titanium alloy-hydroxyapatite (Ti-HA) with various volume fraction gradient exponents n=0.0, 0.1, 0.5, and 1.0. This study is the first to consider an FGFP with a combination of different profiles and cross-sections in a non-bonded implant-bone interface. The results show that the strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP with different geometrical configurations, which correspond to a reduction in stress shielding and subsequently decrease bone resorption. Simultaneously, the interface stresses in the bone-implant contact region have limited variations for all combinations of profiles and cross-sections. Therefore, FGFP can be employed to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease stress shielding and interface stress. This condition results in an increase in the total lifespan of the hip replacement. © 2014 Elsevier Ltd.
2014
Finite element analysis; Functionally graded femoral prosthesis; Hip replacement; Stress shielding
01 Pubblicazione su rivista::01a Articolo in rivista
Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations / Oshkour, A.A., Osman, N.A.A., Bayat, M., Afshar, R., Berto, F.. - In: MATERIALS & DESIGN. - ISSN 0264-1275. - 56:(2014), pp. 998-1008. [10.1016/j.matdes.2013.12.054]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1688603
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 59
  • ???jsp.display-item.citation.isi??? 51
social impact