A strain-based multiaxial fatigue criterion previously proposed for fatigue assessment of unnotched specimens is here extended to the case of notched ones. Such a criterion is a reformulation of the stress-based multiaxial High-Cycle Fatigue (HCF) criterion by Carpinteri and Spagnoli. The extension herein presented considers as the critical point, where to perform the fatigue assessment, the material point located at a certain distance from the notch tip, depending such a distance on both the biaxiality ratio (defined as the ratio between the applied shear stress amplitude and the normal stress amplitude) and the control volume radii R1 (related to Mode I) and R3 (related to Mode III). Some multiaxial fatigue data related to specimens made of titanium grade 5 alloy (Ti–6Al–4V) and weakened by sharp notches are examined to validate the extended criterion. © 2016 Elsevier Ltd
Fatigue assessment of notched specimens by means of a critical plane-based criterion and energy concepts / Carpinteri, A.; Berto, F.; Campagnolo, A.; Fortese, G.; Ronchei, C.; Scorza, D.; Vantadori, S.. - In: THEORETICAL AND APPLIED FRACTURE MECHANICS. - ISSN 0167-8442. - 84:(2016), pp. 57-63. [10.1016/j.tafmec.2016.03.003]
Fatigue assessment of notched specimens by means of a critical plane-based criterion and energy concepts
Berto F.;Ronchei C.;Scorza D.;Vantadori S.
2016
Abstract
A strain-based multiaxial fatigue criterion previously proposed for fatigue assessment of unnotched specimens is here extended to the case of notched ones. Such a criterion is a reformulation of the stress-based multiaxial High-Cycle Fatigue (HCF) criterion by Carpinteri and Spagnoli. The extension herein presented considers as the critical point, where to perform the fatigue assessment, the material point located at a certain distance from the notch tip, depending such a distance on both the biaxiality ratio (defined as the ratio between the applied shear stress amplitude and the normal stress amplitude) and the control volume radii R1 (related to Mode I) and R3 (related to Mode III). Some multiaxial fatigue data related to specimens made of titanium grade 5 alloy (Ti–6Al–4V) and weakened by sharp notches are examined to validate the extended criterion. © 2016 Elsevier LtdFile | Dimensione | Formato | |
---|---|---|---|
Carpinteri_Fatigue-assessment-notched_2016.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
843.51 kB
Formato
Adobe PDF
|
843.51 kB | Adobe PDF | Contatta l'autore |