Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients’ radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients’ characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4−35.9) seconds, the median radiation emission dose was 19.3 (13.2−27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33−0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.

Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation / Leoni, MATTEO LUIGI GIUSEPPE; Vitali, Sara; Micheli, Fabrizio; Mercieri, Marco; Varrassi, Giustino; Casale, Roberto; Occhigrossi, Felice; Giordano, Carlo. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 11:24(2022), pp. 1-10. [10.3390/jcm11247424]

Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation

Matteo Luigi Giuseppe Leoni
;
Sara Vitali;Fabrizio Micheli;Marco Mercieri;
2022

Abstract

Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients’ radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients’ characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4−35.9) seconds, the median radiation emission dose was 19.3 (13.2−27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33−0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.
2022
disc herniation; ozone chemonucleolysis; radiation exposure
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation / Leoni, MATTEO LUIGI GIUSEPPE; Vitali, Sara; Micheli, Fabrizio; Mercieri, Marco; Varrassi, Giustino; Casale, Roberto; Occhigrossi, Felice; Giordano, Carlo. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 11:24(2022), pp. 1-10. [10.3390/jcm11247424]
File allegati a questo prodotto
File Dimensione Formato  
Leoni_Radiation-Exposure_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 504.15 kB
Formato Adobe PDF
504.15 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1687559
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact