(1) Benign hyperpigmentations are a common problem in cosmetic dermatology. Melasma, solar lentigo, and other acquired hyperpigmentations represent an aesthetic issue for an increasing number of patients. The gold standard in managing this condition is currently 1064/532 nanometers (nm) Q-Switched lasers. This study reports our experience on the use of a Q-switched laser with a nanosecond pulse to treat these conditions. (2) Methods: A total of 96 patients asking for benign hyperpigmentation removal were consecutively enrolled at the Magna Graecia University of Catanzaro and Tor Vergata University of Rome. Treating parameters were the following: 1064 nm with a pulse duration of 6 nanoseconds (ns) for dermic lesions and 532 nm with 6 ns for epidermal ones. Up to five treatments with a minimum interval between laser treatments of thirty days were performed. A follow-up visit three months after the last session assessed patient satisfaction with a Visual Analogue Scale (VAS). Two blinded dermatologists assessed the cosmetic result using a five-point scale comparing pictures before treatment and at follow-up. (3) Results: 96 patients were included; 47 participants were women (49.0%) and 49 men (51.0%). The mean reported age was 50.0 ± 17.3 years. All patients reached a good to complete hyperpigmentation removal at the dermatological evaluation with a mean VAS score of 8.91 ± 1.07. (4) Conclusions: Q Switched 1064/532 nm laser may be considered the gold standard treatment for benign hyperpigmentations. Our results confirm the literature findings on the effectiveness of these devices.

Nanosecond Q-switched 1064/532 nm laser to treat hyperpigmentations. a double center retrospective study / Nisticò, Steven Paul; Cannarozzo, Giovanni; Provenzano, Eugenio; Tamburi, Federica; Fazia, Gilda; Sannino, Mario; Negosanti, Francesca; Del Duca, Ester; Patruno, Cataldo; Bennardo, Luigi. - In: CLINICAL PRACTICE. - ISSN 2044-9038. - 11:4(2021), pp. 708-714. [10.3390/clinpract11040086]

Nanosecond Q-switched 1064/532 nm laser to treat hyperpigmentations. a double center retrospective study

Nisticò, Steven Paul
;
Del Duca, Ester;
2021

Abstract

(1) Benign hyperpigmentations are a common problem in cosmetic dermatology. Melasma, solar lentigo, and other acquired hyperpigmentations represent an aesthetic issue for an increasing number of patients. The gold standard in managing this condition is currently 1064/532 nanometers (nm) Q-Switched lasers. This study reports our experience on the use of a Q-switched laser with a nanosecond pulse to treat these conditions. (2) Methods: A total of 96 patients asking for benign hyperpigmentation removal were consecutively enrolled at the Magna Graecia University of Catanzaro and Tor Vergata University of Rome. Treating parameters were the following: 1064 nm with a pulse duration of 6 nanoseconds (ns) for dermic lesions and 532 nm with 6 ns for epidermal ones. Up to five treatments with a minimum interval between laser treatments of thirty days were performed. A follow-up visit three months after the last session assessed patient satisfaction with a Visual Analogue Scale (VAS). Two blinded dermatologists assessed the cosmetic result using a five-point scale comparing pictures before treatment and at follow-up. (3) Results: 96 patients were included; 47 participants were women (49.0%) and 49 men (51.0%). The mean reported age was 50.0 ± 17.3 years. All patients reached a good to complete hyperpigmentation removal at the dermatological evaluation with a mean VAS score of 8.91 ± 1.07. (4) Conclusions: Q Switched 1064/532 nm laser may be considered the gold standard treatment for benign hyperpigmentations. Our results confirm the literature findings on the effectiveness of these devices.
2021
Q switched laser; benign hyperpigmentations; melasma; solar lentigo
01 Pubblicazione su rivista::01a Articolo in rivista
Nanosecond Q-switched 1064/532 nm laser to treat hyperpigmentations. a double center retrospective study / Nisticò, Steven Paul; Cannarozzo, Giovanni; Provenzano, Eugenio; Tamburi, Federica; Fazia, Gilda; Sannino, Mario; Negosanti, Francesca; Del Duca, Ester; Patruno, Cataldo; Bennardo, Luigi. - In: CLINICAL PRACTICE. - ISSN 2044-9038. - 11:4(2021), pp. 708-714. [10.3390/clinpract11040086]
File allegati a questo prodotto
File Dimensione Formato  
Nisticò_Nanosecond_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.75 MB
Formato Adobe PDF
3.75 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1687127
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact