this paper presents a measurement procedure for analyzing the dielectric properties of cells using descriptive statistics. The study focuses on four cancer cell lines (MDA-MB-231 and MCF-12 7 breast cancer, SaOS-2, and 143B osteosarcoma) and DMEM culture medium, utilizing the Lorentzian fit model of the Return Loss function. The measurements are performed using a circular patch resonator with a 40 mm diameter, powered by a miniVNA operating in the frequency range of 1 MHz to 3 GHz. Eight specimens are prepared for each group to ensure reliability, and the Return Loss is recorded ten times for each specimen. Various statistical parameters are calculated and evaluated, including the average value, standard deviation, coefficient of variation, and relative error between the average and the first values. The results demonstrate that one single acquisition highly represents the entire set of ten data points, especially for the resonant frequency, with an accuracy error lower than 0.05%. These findings have significant implications for the methodological approach to detecting cells' dielectric properties, as they substantially reduce time and preserve the 22 specimens without compromising the accuracy of the experimental results.

Determination of a measurement procedure for the study of cells’ dielectric properties through descriptive statistic / D’Alvia, Livio; Peruzzi, Barbara; Apa, Ludovica; DEL PRETE, Zaccaria; Rizzuto, Emanuele. - In: BIOENGINEERING. - ISSN 2306-5354. - (2023), pp. 1-13. [10.3390/bioengineering10080907]

Determination of a measurement procedure for the study of cells’ dielectric properties through descriptive statistic

Livio D’Alvia;Ludovica Apa;Zaccaria del prete;Emanuele rizzuto
2023

Abstract

this paper presents a measurement procedure for analyzing the dielectric properties of cells using descriptive statistics. The study focuses on four cancer cell lines (MDA-MB-231 and MCF-12 7 breast cancer, SaOS-2, and 143B osteosarcoma) and DMEM culture medium, utilizing the Lorentzian fit model of the Return Loss function. The measurements are performed using a circular patch resonator with a 40 mm diameter, powered by a miniVNA operating in the frequency range of 1 MHz to 3 GHz. Eight specimens are prepared for each group to ensure reliability, and the Return Loss is recorded ten times for each specimen. Various statistical parameters are calculated and evaluated, including the average value, standard deviation, coefficient of variation, and relative error between the average and the first values. The results demonstrate that one single acquisition highly represents the entire set of ten data points, especially for the resonant frequency, with an accuracy error lower than 0.05%. These findings have significant implications for the methodological approach to detecting cells' dielectric properties, as they substantially reduce time and preserve the 22 specimens without compromising the accuracy of the experimental results.
2023
descriptive statistic; metrological evaluation; dielectric properties; biosensor; non-inva-24 sive measurements; cancer cell lines; osteosarcoma; breast cancer
01 Pubblicazione su rivista::01a Articolo in rivista
Determination of a measurement procedure for the study of cells’ dielectric properties through descriptive statistic / D’Alvia, Livio; Peruzzi, Barbara; Apa, Ludovica; DEL PRETE, Zaccaria; Rizzuto, Emanuele. - In: BIOENGINEERING. - ISSN 2306-5354. - (2023), pp. 1-13. [10.3390/bioengineering10080907]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1685687
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact