Background: Humeral shaft fractures account for 1% to 3% of all fractures and approximately 20% of all fracture involving the humerus. The prevalence of non-union for diaphyseal humeral fractures has been reported as 1% to 10% after non-surgical and 10% to 15% after surgical management. Various devices used in treatment of humeral diaphyseal non-union are limited contact dynamic compression plates, locking compression plate (LCP), wave plates, humerus interlocking nail (IMN), Ilizarov external fixators and bone graft struts. Case Description: A 68-year-old man reported a humeral shaft fracture on the left side, due to a simple fall. It was reduced and fixed by IMN. He underwent clinical and radiological follow up. Three months after the intervention, due to persistent pain and impaired function of the left shoulder, the nail was removed and a cemented endoprosthesis was implanted. 3 years later, unsatisfied with the results, he came to our attention and was diagnosed an atrophic non-union in the site of the previous humeral shaft fracture. Moreover, the exams showed a rotator cuff insufficiency. It was decided to perform a single-stage intervention to achieve two goals: cure the humeral shaft non-union and restore the function of the left shoulder. The cemented endoprosthesis was removed, followed by an extensive curettage of the non-union site. A reverse prosthesis was implanted, with an extra-long stem used to stabilize the non-union site, as it was an IMN. An allograft was harvested from a cadaver femur and fixed with two metal cerclages. The patient underwent clinical and radiological follow-up. Complete healing was achieved 8 months later. Conclusion: Humeral shaft nonunion still represent a pathology that pose a serious problem to the surgeon. A correct management should include an accurate pre-operative planning, to achieve the best result possible for the patient.

An Unusual Case of Humeral Shaft Non-Union / Chillemi, Claudio; Chillemi, Claudio; Damo, Marco; Russo, Nello; Paolicelli, Domenico; Carli, Stefano. - In: INTERNATIONAL JOURNAL OF SURGICAL CASE REPORTS. - ISSN 2674-4171. - (2020), pp. 1-4. [10.31487/j.IJSCR.2020.03.02]

An Unusual Case of Humeral Shaft Non-Union

Damo, Marco;Paolicelli, Domenico;Carli, Stefano
2020

Abstract

Background: Humeral shaft fractures account for 1% to 3% of all fractures and approximately 20% of all fracture involving the humerus. The prevalence of non-union for diaphyseal humeral fractures has been reported as 1% to 10% after non-surgical and 10% to 15% after surgical management. Various devices used in treatment of humeral diaphyseal non-union are limited contact dynamic compression plates, locking compression plate (LCP), wave plates, humerus interlocking nail (IMN), Ilizarov external fixators and bone graft struts. Case Description: A 68-year-old man reported a humeral shaft fracture on the left side, due to a simple fall. It was reduced and fixed by IMN. He underwent clinical and radiological follow up. Three months after the intervention, due to persistent pain and impaired function of the left shoulder, the nail was removed and a cemented endoprosthesis was implanted. 3 years later, unsatisfied with the results, he came to our attention and was diagnosed an atrophic non-union in the site of the previous humeral shaft fracture. Moreover, the exams showed a rotator cuff insufficiency. It was decided to perform a single-stage intervention to achieve two goals: cure the humeral shaft non-union and restore the function of the left shoulder. The cemented endoprosthesis was removed, followed by an extensive curettage of the non-union site. A reverse prosthesis was implanted, with an extra-long stem used to stabilize the non-union site, as it was an IMN. An allograft was harvested from a cadaver femur and fixed with two metal cerclages. The patient underwent clinical and radiological follow-up. Complete healing was achieved 8 months later. Conclusion: Humeral shaft nonunion still represent a pathology that pose a serious problem to the surgeon. A correct management should include an accurate pre-operative planning, to achieve the best result possible for the patient.
2020
Arthroplasty, Shoulder, Fracture, Non-Union
01 Pubblicazione su rivista::01a Articolo in rivista
An Unusual Case of Humeral Shaft Non-Union / Chillemi, Claudio; Chillemi, Claudio; Damo, Marco; Russo, Nello; Paolicelli, Domenico; Carli, Stefano. - In: INTERNATIONAL JOURNAL OF SURGICAL CASE REPORTS. - ISSN 2674-4171. - (2020), pp. 1-4. [10.31487/j.IJSCR.2020.03.02]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1684141
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact