Purpose: To evaluate the efficacy of two hydrodynamic sinus lifting procedures and to successfully place immediate implants in maxillary posterior sites that have a compromised native bone as a result of periodontal or endodontic disease. Patients and Methods: A total of 26 patient sites were enrolled with 13 sites each in the Minimally Invasive Antral Membrane Balloon Elevation (MIAMBE) and Drill Integrated Hydrodynamics for the transcrestal sinus floor elevation (DIHSFE) groups who received transcrestal sinus floor elevation followed by immediate implant placement. Clinical parameters such as sinus membrane perforations, nasal bleeding, postoperative sinusitis, VAS scores at Day-7 for pain and discomfort, primary implant stability and time taken were evaluated. Results: The DIHSFE had greater sinus membrane perforations and incidence of nasal bleeding when compared with MIAMBE with (p = 0.066) and (p = 0.141). Post-operative sinusitis was evident in both the groups with (p = 0.619). The mean VAS score was statistically significant between both the groups (p ≤ 0.005). The insertion torque values, and mean time taken for surgical procedure was not statistically significant between groups. Conclusion: The present study highlighted that MIAMBE is superior to DIHSFE in its ability to cause less severe patient morbidities and post-operative complications.

Efficacy of two different hydrodynamic sinus lift systems for atraumatic elevation in immediate implant placement / Praveen, A. A.; Venkadassalapathy, S.; Victor, D. J.; Prakash, P. S. G.; Umesh, S. G.; Baeshen, H. A.; Balaji, T. M.; Patil, S.; Reda, R.; Testarelli, L.. - In: PATIENT PREFERENCE AND ADHERENCE. - ISSN 1177-889X. - 17:(2023), pp. 1197-1207. [10.2147/PPA.S403036]

Efficacy of two different hydrodynamic sinus lift systems for atraumatic elevation in immediate implant placement

Reda R.
Penultimo
Methodology
;
Testarelli L.
Ultimo
Conceptualization
2023

Abstract

Purpose: To evaluate the efficacy of two hydrodynamic sinus lifting procedures and to successfully place immediate implants in maxillary posterior sites that have a compromised native bone as a result of periodontal or endodontic disease. Patients and Methods: A total of 26 patient sites were enrolled with 13 sites each in the Minimally Invasive Antral Membrane Balloon Elevation (MIAMBE) and Drill Integrated Hydrodynamics for the transcrestal sinus floor elevation (DIHSFE) groups who received transcrestal sinus floor elevation followed by immediate implant placement. Clinical parameters such as sinus membrane perforations, nasal bleeding, postoperative sinusitis, VAS scores at Day-7 for pain and discomfort, primary implant stability and time taken were evaluated. Results: The DIHSFE had greater sinus membrane perforations and incidence of nasal bleeding when compared with MIAMBE with (p = 0.066) and (p = 0.141). Post-operative sinusitis was evident in both the groups with (p = 0.619). The mean VAS score was statistically significant between both the groups (p ≤ 0.005). The insertion torque values, and mean time taken for surgical procedure was not statistically significant between groups. Conclusion: The present study highlighted that MIAMBE is superior to DIHSFE in its ability to cause less severe patient morbidities and post-operative complications.
2023
immediate implants; insertion torque values; minimally invasive antral membrane balloon elevation; postoperative sinusitis; sinus membrane perforation
01 Pubblicazione su rivista::01a Articolo in rivista
Efficacy of two different hydrodynamic sinus lift systems for atraumatic elevation in immediate implant placement / Praveen, A. A.; Venkadassalapathy, S.; Victor, D. J.; Prakash, P. S. G.; Umesh, S. G.; Baeshen, H. A.; Balaji, T. M.; Patil, S.; Reda, R.; Testarelli, L.. - In: PATIENT PREFERENCE AND ADHERENCE. - ISSN 1177-889X. - 17:(2023), pp. 1197-1207. [10.2147/PPA.S403036]
File allegati a questo prodotto
File Dimensione Formato  
Praveen_Efficacy of two_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1681992
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
social impact