The purpose of this study is to evaluate the influence of implant scanbody (ISB) material and operator on scanning fluency and polygonal mesh numbers of a confocal microscopy intraoral scanning (IOS). An edentulous maxillary master model with 6 implant analogues was assembled. Thereafter 3 ISBs featured with same geometry but different materials (polyetheretherketone (PK), titanium (T) and PK with a titanium base (PKT)) were produce and scanned according to a randomized sequence by three different operators. The confocal microscopy IOS resulted in 45 STL test files that were processed to a dedicate software to obtain the request data. The overall analysis of fluency (imm/sec) showed the following results: mean 11.997 imm/sec, SD 2.335. The multivariate analysis showed statistical significance of material (p<.0001) and operator (p<.0001) influence. The univariate analysis referred to polygonal mesh numbers expressed the following results: mean 30327.8, SD 2432.5. The multivariate analysis stressed how there is a related effect of materials (p<.0001) and operator (p=0.0205).PKT represented the material with the best results for both. Analyzing the overall distribution histogram for scanning fluency, the IOS device seems to work with higher frequency at level of 12 imm/sec. The distribution of the measurements in the reference histograms showed an effect related to both variables referring to scanning fluency as well as to polygonal mesh numbers. Operator can be considered as a random effect; regarding the materials, the difference between PKT and PK can be related to the different base material. The dissimilar optical properties of T justify the different behavior.

Influence of implant scanbody material and operator on scanning fluency and polygonal mesh numbers of digital impression: an in vitro study / Arcuri, L.; Lio, F.; Papa, A.; Nardi, A.; Barlattani, A.. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 33:6 Suppl. 2(2019), pp. 179-188.

Influence of implant scanbody material and operator on scanning fluency and polygonal mesh numbers of digital impression: an in vitro study

Arcuri L.
Primo
;
2019

Abstract

The purpose of this study is to evaluate the influence of implant scanbody (ISB) material and operator on scanning fluency and polygonal mesh numbers of a confocal microscopy intraoral scanning (IOS). An edentulous maxillary master model with 6 implant analogues was assembled. Thereafter 3 ISBs featured with same geometry but different materials (polyetheretherketone (PK), titanium (T) and PK with a titanium base (PKT)) were produce and scanned according to a randomized sequence by three different operators. The confocal microscopy IOS resulted in 45 STL test files that were processed to a dedicate software to obtain the request data. The overall analysis of fluency (imm/sec) showed the following results: mean 11.997 imm/sec, SD 2.335. The multivariate analysis showed statistical significance of material (p<.0001) and operator (p<.0001) influence. The univariate analysis referred to polygonal mesh numbers expressed the following results: mean 30327.8, SD 2432.5. The multivariate analysis stressed how there is a related effect of materials (p<.0001) and operator (p=0.0205).PKT represented the material with the best results for both. Analyzing the overall distribution histogram for scanning fluency, the IOS device seems to work with higher frequency at level of 12 imm/sec. The distribution of the measurements in the reference histograms showed an effect related to both variables referring to scanning fluency as well as to polygonal mesh numbers. Operator can be considered as a random effect; regarding the materials, the difference between PKT and PK can be related to the different base material. The dissimilar optical properties of T justify the different behavior.
2019
digital impression; intraoral scanner; implant scanbody; scanning fluency; polygonal mesh
01 Pubblicazione su rivista::01a Articolo in rivista
Influence of implant scanbody material and operator on scanning fluency and polygonal mesh numbers of digital impression: an in vitro study / Arcuri, L.; Lio, F.; Papa, A.; Nardi, A.; Barlattani, A.. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 33:6 Suppl. 2(2019), pp. 179-188.
File allegati a questo prodotto
File Dimensione Formato  
Arcuri_postprint_Influence of implant_2019.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 950.11 kB
Formato Adobe PDF
950.11 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1681928
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 4
social impact