Herein, we report on the synthesis and high-performance liquid chromatography (HPLC) resolution of a new atropisomeric C2-symmetry chiral monomer based on the 3,3′-bithiophene core, which was developed to produce novel, inherently oligomeric chiral electroactive materials. The analytical enantioseparation was optimized using the cellulose-type Chiralpak IB-3 column and a mixture of n-hexane–methanol–dichloromethane 90:5:5 (v/v/v) as the mobile phase. During the scale-up of the enantioseparation analytical conditions to a semipreparative level, remarkable deformations in the HPLC profile, such as peak splitting and plateau zones between enantiomeric peaks, were observed. We demonstrate the effects of sample diluent as they relate to distorted peak profiles, as well as provide experimental solutions to prevent the disturbing phenomenon. The optimized chromatographic conditions were exploited to collect milligram amounts of the enantiopure sample, which was submitted to chiroptical and stereochemical characterization studies.

A new C2-symmetric atropisomeric thiophene-based monomer for inherently chiral electroactive materials. Synthesis, HPLC resolution, and absolute configuration assignment / Rosetti, Alessia; Apolloni, Giulio; Villani, Claudio; Benincori, Tiziana; Cirilli, Roberto. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 13:3(2023). [10.3390/app13031407]

A new C2-symmetric atropisomeric thiophene-based monomer for inherently chiral electroactive materials. Synthesis, HPLC resolution, and absolute configuration assignment

Alessia Rosetti;Claudio Villani;
2023

Abstract

Herein, we report on the synthesis and high-performance liquid chromatography (HPLC) resolution of a new atropisomeric C2-symmetry chiral monomer based on the 3,3′-bithiophene core, which was developed to produce novel, inherently oligomeric chiral electroactive materials. The analytical enantioseparation was optimized using the cellulose-type Chiralpak IB-3 column and a mixture of n-hexane–methanol–dichloromethane 90:5:5 (v/v/v) as the mobile phase. During the scale-up of the enantioseparation analytical conditions to a semipreparative level, remarkable deformations in the HPLC profile, such as peak splitting and plateau zones between enantiomeric peaks, were observed. We demonstrate the effects of sample diluent as they relate to distorted peak profiles, as well as provide experimental solutions to prevent the disturbing phenomenon. The optimized chromatographic conditions were exploited to collect milligram amounts of the enantiopure sample, which was submitted to chiroptical and stereochemical characterization studies.
2023
3,3′-dibenzothiophene derivative; semi-preparative HPLC; enantioseparation; absolute configuration; electronic circular dichroism
01 Pubblicazione su rivista::01a Articolo in rivista
A new C2-symmetric atropisomeric thiophene-based monomer for inherently chiral electroactive materials. Synthesis, HPLC resolution, and absolute configuration assignment / Rosetti, Alessia; Apolloni, Giulio; Villani, Claudio; Benincori, Tiziana; Cirilli, Roberto. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 13:3(2023). [10.3390/app13031407]
File allegati a questo prodotto
File Dimensione Formato  
Rosetti_A-new-C2-symmetric_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.61 MB
Formato Adobe PDF
1.61 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1681384
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact