Objective: Carotid artery stenting (CAS) has been shown to protect patients from future stroke with long term efficacy comparable with that of carotid endarterectomy (CEA). However, differences in outcome following CAS and CEA still exist, consisting primarily of a higher rate of neurological events occurring in the peri-procedural period after CAS, caused by embolisation from aortic archmanipulation, plaque debris, and probably air embolism, the latter reported in literature after thoracic endovascular aortic repair, due to air trap in the thoracic endograft flushed only by saline solution. The present authors suppose that the same mechanism could be responsible for air microembolisation during CAS, and microembolisation has been documented as a cause of neurocognitive decline. New generations of dual layer mesh covered carotid stent systems increase plaque coverage with a reduction of debris, but their design also increases the risk of more air being trapped in the stent shaft because of multiple components, thus increasing the risk of air brain embolism. The present authors present the protocol for a study assessing effectiveness of a new technique for reducing air microembolism during CAS. After an in vitro pipeline test of a c-guard stent, saline solution washing and deployment demonstrating little bubble air release, the effectiveness of CO2 flushing of the stent to prevent air microembolism after CAS will be investigated. Diagnostic and clinical outcomes will be analysed. Methods: In two university referral teaching hospitals, consecutive patients (divided into two groups) affected by asymptomatic carotid stenosis   70% and enrolled for CAS will be submitted to preoperative diffusion-weighted magnetic resonance imaging (DWMRI) scan, to exclude the presence of pre-operative silent cerebral lesions. Patients will be randomised to CAS using c-guard stent with or without CO2 flushing using a computer generated random allocation sequence with a blocked randomisation by an allocation ratio 1:1. A transfemoral approach through an 8 fr. arterial sheath will be established, and an initial intravenous heparin bolus will be administered, followed by a continuous intra-arterial infusion of heparinised saline solution through the guiding catheter/reinforced sheath in a closed flushing system to avoid external air bubble introduction. A distal cerebral protection by filter wire will be used in all patients. The c-guard stent flushing will be done according to the instructions for use with saline solution for the control group, preceded by medical CO2 flushing for the study group. DW-MRI will be performed within 24 hours after the intervention. Moreover, pre- and post-operative Mini-Mental-State-Examination Tests (MMSE) will be conducted, as well as serum S100b neurobiomarker assessment. Results: The primary endpoint of the study will be the evaluation of technical and clinical success of CAS with or without CO2 stent flushing peri-operatively, at 24 hours, 30 days, and at one and two years. The following secondary endpoints will also be assessed: operative time, radiation exposure and contrast medium use, postoperative DW-MRI new lesions, neurobiomarkers, and MMSE variation within 24 hours. After that at 30 days, one and two years, an MMSE test will be evaluated. Sample size estimation is 80 patients (40 patients per each group). The study will start in June 2022 and the final patient is expected to be treated by June 2023. The estimated study completion date should be June 2025. Conclusion: This study will aim to show, in real world practice, the effectiveness of CO2 stent flushing to prevent cerebral embolism during CASand its effectiveness in neurocognitive decline prevention.

Carbon Dioxide Stent Flushing To Prevent Cerebral Air Microembolism During Carotid Artery Stenting. Protocol for a Randomised Study / Mansour, W.; Capoccia, L.; Sirignano, P.; Di Girolamo, A.; Molinari, A.; Bozzao, A.; Taurino, M.; Di Marzo, L.. - In: EJVES VASCULAR FORUM. - ISSN 2666-688X. - 58:(2023), pp. 35-35. [10.1016/j.ejvsvf.2023.02.008]

Carbon Dioxide Stent Flushing To Prevent Cerebral Air Microembolism During Carotid Artery Stenting. Protocol for a Randomised Study

Mansour, W.
;
Capoccia, L.;Sirignano, P.;Di Girolamo, A.;Molinari, A.;Bozzao, A.;Taurino, M.;Di Marzo, L.
2023

Abstract

Objective: Carotid artery stenting (CAS) has been shown to protect patients from future stroke with long term efficacy comparable with that of carotid endarterectomy (CEA). However, differences in outcome following CAS and CEA still exist, consisting primarily of a higher rate of neurological events occurring in the peri-procedural period after CAS, caused by embolisation from aortic archmanipulation, plaque debris, and probably air embolism, the latter reported in literature after thoracic endovascular aortic repair, due to air trap in the thoracic endograft flushed only by saline solution. The present authors suppose that the same mechanism could be responsible for air microembolisation during CAS, and microembolisation has been documented as a cause of neurocognitive decline. New generations of dual layer mesh covered carotid stent systems increase plaque coverage with a reduction of debris, but their design also increases the risk of more air being trapped in the stent shaft because of multiple components, thus increasing the risk of air brain embolism. The present authors present the protocol for a study assessing effectiveness of a new technique for reducing air microembolism during CAS. After an in vitro pipeline test of a c-guard stent, saline solution washing and deployment demonstrating little bubble air release, the effectiveness of CO2 flushing of the stent to prevent air microembolism after CAS will be investigated. Diagnostic and clinical outcomes will be analysed. Methods: In two university referral teaching hospitals, consecutive patients (divided into two groups) affected by asymptomatic carotid stenosis   70% and enrolled for CAS will be submitted to preoperative diffusion-weighted magnetic resonance imaging (DWMRI) scan, to exclude the presence of pre-operative silent cerebral lesions. Patients will be randomised to CAS using c-guard stent with or without CO2 flushing using a computer generated random allocation sequence with a blocked randomisation by an allocation ratio 1:1. A transfemoral approach through an 8 fr. arterial sheath will be established, and an initial intravenous heparin bolus will be administered, followed by a continuous intra-arterial infusion of heparinised saline solution through the guiding catheter/reinforced sheath in a closed flushing system to avoid external air bubble introduction. A distal cerebral protection by filter wire will be used in all patients. The c-guard stent flushing will be done according to the instructions for use with saline solution for the control group, preceded by medical CO2 flushing for the study group. DW-MRI will be performed within 24 hours after the intervention. Moreover, pre- and post-operative Mini-Mental-State-Examination Tests (MMSE) will be conducted, as well as serum S100b neurobiomarker assessment. Results: The primary endpoint of the study will be the evaluation of technical and clinical success of CAS with or without CO2 stent flushing peri-operatively, at 24 hours, 30 days, and at one and two years. The following secondary endpoints will also be assessed: operative time, radiation exposure and contrast medium use, postoperative DW-MRI new lesions, neurobiomarkers, and MMSE variation within 24 hours. After that at 30 days, one and two years, an MMSE test will be evaluated. Sample size estimation is 80 patients (40 patients per each group). The study will start in June 2022 and the final patient is expected to be treated by June 2023. The estimated study completion date should be June 2025. Conclusion: This study will aim to show, in real world practice, the effectiveness of CO2 stent flushing to prevent cerebral embolism during CASand its effectiveness in neurocognitive decline prevention.
2023
carotid stenting; microembolic events
01 Pubblicazione su rivista::01h Abstract in rivista
Carbon Dioxide Stent Flushing To Prevent Cerebral Air Microembolism During Carotid Artery Stenting. Protocol for a Randomised Study / Mansour, W.; Capoccia, L.; Sirignano, P.; Di Girolamo, A.; Molinari, A.; Bozzao, A.; Taurino, M.; Di Marzo, L.. - In: EJVES VASCULAR FORUM. - ISSN 2666-688X. - 58:(2023), pp. 35-35. [10.1016/j.ejvsvf.2023.02.008]
File allegati a questo prodotto
File Dimensione Formato  
Mansour_Abstract O-103-Carbon-Dioxide-Stent-Flushing_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 58.28 kB
Formato Adobe PDF
58.28 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1678119
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact