This study applies the single drop techniques to compare the efficacy of Raman, FT – NIR, and FT-MIR spectral imaging to quantify lactose concentration in dried whole milk on different metallic surfaces. Drying the samples avoids degradation problems such as water evaporation or oil degradation and scattering due to micelles. Spectral imaging techniques minimise sampling issues while also describing the sample spatial variation. The mean spectra of pre-processed images were used to build PLS regression models to predict lactose concentration. Raman, FT – NIR (5600–3730 cm−1), FT–MIR (3533–600 cm−1) models and the model obtained using the fusion of the three ranges were built independently and compared. This study confirms that is possible to quantify lactose rapidly using spectral imaging without adding standard references: the minimum RMSEP = 2.8 mg/mL (R2 = 0.98) was achieved with FT – MIR spectral imaging.

Single-drop technique for lactose prediction in dry milk on metallic surfaces: Comparison of Raman, FT – NIR, and FT – MIR spectral imaging / Caponigro, V.; Marini, F.; Scannell, A. G. M.; Gowen, A. A.. - In: FOOD CONTROL. - ISSN 0956-7135. - 144:(2023), pp. 1-9. [10.1016/j.foodcont.2022.109351]

Single-drop technique for lactose prediction in dry milk on metallic surfaces: Comparison of Raman, FT – NIR, and FT – MIR spectral imaging

Marini F.
Secondo
;
2023

Abstract

This study applies the single drop techniques to compare the efficacy of Raman, FT – NIR, and FT-MIR spectral imaging to quantify lactose concentration in dried whole milk on different metallic surfaces. Drying the samples avoids degradation problems such as water evaporation or oil degradation and scattering due to micelles. Spectral imaging techniques minimise sampling issues while also describing the sample spatial variation. The mean spectra of pre-processed images were used to build PLS regression models to predict lactose concentration. Raman, FT – NIR (5600–3730 cm−1), FT–MIR (3533–600 cm−1) models and the model obtained using the fusion of the three ranges were built independently and compared. This study confirms that is possible to quantify lactose rapidly using spectral imaging without adding standard references: the minimum RMSEP = 2.8 mg/mL (R2 = 0.98) was achieved with FT – MIR spectral imaging.
2023
aluminium; FT; FT-MIR; hyperspectral; imaging; lactose; lactose (PubChem CID: 62223); milk; NIR; PLS; Raman; spectral; stainless steel
01 Pubblicazione su rivista::01a Articolo in rivista
Single-drop technique for lactose prediction in dry milk on metallic surfaces: Comparison of Raman, FT – NIR, and FT – MIR spectral imaging / Caponigro, V.; Marini, F.; Scannell, A. G. M.; Gowen, A. A.. - In: FOOD CONTROL. - ISSN 0956-7135. - 144:(2023), pp. 1-9. [10.1016/j.foodcont.2022.109351]
File allegati a questo prodotto
File Dimensione Formato  
Caponigro_Single-drop_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.19 MB
Formato Adobe PDF
4.19 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1677487
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact