gamma-ray spectrometry is a well-known technique in environmental radioactivity measurements where easily handled systems are needed. Scintillators coupled to a photomultiplier tube (PMT), are typically favoured over solid-state detectors as mobile spectrometers. Replacing PMT with position sensitive devices represents an innovative solution that provides the evaluation of the interaction point of the incident radiation. The knowledge of spectrometry as a function of the depth of interaction (DoI) assures a better understanding of the spectrum and a more reliable identification of the source. In this paper, the efficiency of a simple DoI estimator has been studied using a CRY018 monolithic crystal coupled to a multi-anode photomultiplier tube. The DoI estimator has been evaluated studying charge distributions and the dependency of spectrometric properties on the DoI has been qualitatively analyzed. The estimator has shown to be highly sensitive to the DoI, enabling a better understanding of the internal interaction processes of light and an efficient rejection of the background component on the spectra. The novelty of this work lies in the application of the DoI selection in spectrometry made available by the use of MAPMT. The proposed method is practical since it does not require complicated hardware solutions or complex computational procedures.

A novel method for spectrometry based on imaging systems / Falconi, Rita; Sorbino, Stefania; Pani, Roberto; Indovina, Luca. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 12:3(2022), pp. 1-14. [10.3390/app12031657]

A novel method for spectrometry based on imaging systems

Rita Falconi
;
Stefania Sorbino;Roberto Pani;
2022

Abstract

gamma-ray spectrometry is a well-known technique in environmental radioactivity measurements where easily handled systems are needed. Scintillators coupled to a photomultiplier tube (PMT), are typically favoured over solid-state detectors as mobile spectrometers. Replacing PMT with position sensitive devices represents an innovative solution that provides the evaluation of the interaction point of the incident radiation. The knowledge of spectrometry as a function of the depth of interaction (DoI) assures a better understanding of the spectrum and a more reliable identification of the source. In this paper, the efficiency of a simple DoI estimator has been studied using a CRY018 monolithic crystal coupled to a multi-anode photomultiplier tube. The DoI estimator has been evaluated studying charge distributions and the dependency of spectrometric properties on the DoI has been qualitatively analyzed. The estimator has shown to be highly sensitive to the DoI, enabling a better understanding of the internal interaction processes of light and an efficient rejection of the background component on the spectra. The novelty of this work lies in the application of the DoI selection in spectrometry made available by the use of MAPMT. The proposed method is practical since it does not require complicated hardware solutions or complex computational procedures.
2022
environmental radioactivity measurements; DoI determination; g spectrometry; imaging system; multiple sources identification
01 Pubblicazione su rivista::01a Articolo in rivista
A novel method for spectrometry based on imaging systems / Falconi, Rita; Sorbino, Stefania; Pani, Roberto; Indovina, Luca. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 12:3(2022), pp. 1-14. [10.3390/app12031657]
File allegati a questo prodotto
File Dimensione Formato  
Falconi_Novel-method_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.58 MB
Formato Adobe PDF
3.58 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1676532
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact