Background: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. Aims: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. Methods: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. Results: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). Conclusions: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.

Haemodynamic performance and clinical outcomes of transcatheter aortic valve replacement with the self-expanding ACURATE neo2 / Scotti, A.; Pagnesi, M.; Kim, W. K.; Schäfer, U.; Barbanti, M.; Costa, G.; Baggio, S.; Casenghi, M.; De Marco, F.; Vanhaverbeke, M.; Sondergaard, L.; Wolf, A.; Schofer, J.; Ancona, M. B.; Montorfano, M.; Kornowski, R.; Assa, H. V.; Toggweiler, S.; Ielasi, A.; Hildick-Smith, D.; Windecker, S.; Schmidt, A.; Buono, A.; Maffeo, D.; Siqueira, D.; Giannini, F.; Adamo, M.; Massussi, M.; Wood, D. A.; Sinning, J. M.; Van der Heyden, J.; van Ginkel, D. J.; Van Mieghem, N.; Veulemans, V.; Mylotte, D.; Tzalamouras, V.; Taramasso, M.; Estévez-Loureiro, R.; Colombo, A.; Mangieri, A.; Latib, A.. - In: EUROINTERVENTION. - ISSN 1774-024X. - 18:10(2022), pp. 804-811. [10.4244/EIJ-D-22-00289]

Haemodynamic performance and clinical outcomes of transcatheter aortic valve replacement with the self-expanding ACURATE neo2

Casenghi M.;
2022

Abstract

Background: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. Aims: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. Methods: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. Results: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). Conclusions: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.
2022
TAVR, SAVR, Acurate
01 Pubblicazione su rivista::01a Articolo in rivista
Haemodynamic performance and clinical outcomes of transcatheter aortic valve replacement with the self-expanding ACURATE neo2 / Scotti, A.; Pagnesi, M.; Kim, W. K.; Schäfer, U.; Barbanti, M.; Costa, G.; Baggio, S.; Casenghi, M.; De Marco, F.; Vanhaverbeke, M.; Sondergaard, L.; Wolf, A.; Schofer, J.; Ancona, M. B.; Montorfano, M.; Kornowski, R.; Assa, H. V.; Toggweiler, S.; Ielasi, A.; Hildick-Smith, D.; Windecker, S.; Schmidt, A.; Buono, A.; Maffeo, D.; Siqueira, D.; Giannini, F.; Adamo, M.; Massussi, M.; Wood, D. A.; Sinning, J. M.; Van der Heyden, J.; van Ginkel, D. J.; Van Mieghem, N.; Veulemans, V.; Mylotte, D.; Tzalamouras, V.; Taramasso, M.; Estévez-Loureiro, R.; Colombo, A.; Mangieri, A.; Latib, A.. - In: EUROINTERVENTION. - ISSN 1774-024X. - 18:10(2022), pp. 804-811. [10.4244/EIJ-D-22-00289]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1672415
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 16
social impact