In muscular skeletal spine and pelvic tumor, surgery can be performed by a double anterior and posterior approach to decrease the risk of bleeding and opening the tumor; in first one, neurovascular bundles are divided by the mass; in second one, the tumor is resected by posterior or postero-lateral approach. A Gore-Tex mesh could be used as divisor between neurovascular bundles and the tumor to decrease the adhesion formation risk and facilitate tumor removal during second operation if performed after more days. The cohort was composed by a consecutive series of 11 patients underwent to surgery for spine and pelvic tumor where Gore-Tex mesh spacer was placed. In this study, efficiency and tolerability of Gore-Tex mesh were evaluated. No case of adhesion between Gore-Tex mesh and surrounding structures is reported, no case of migration or complications occurred. Gore-Tex mesh use can be considered a useful and safe procedure to decrease the risk of adhesion formation between tumor and surrounding tissue so that to allow the tumor removal easier.

The Gore-Tex biomaterial mesh as temporary divisor in two times surgery for spinal and pelvic tumors / Zoccali, C; Prencipe, U; Favale, L; Di Filippo, F.. - In: MUSCULOSKELETAL SURGERY. - ISSN 2035-5106. - 94:1(2010), pp. 21-24.

The Gore-Tex biomaterial mesh as temporary divisor in two times surgery for spinal and pelvic tumors

Zoccali C;
2010

Abstract

In muscular skeletal spine and pelvic tumor, surgery can be performed by a double anterior and posterior approach to decrease the risk of bleeding and opening the tumor; in first one, neurovascular bundles are divided by the mass; in second one, the tumor is resected by posterior or postero-lateral approach. A Gore-Tex mesh could be used as divisor between neurovascular bundles and the tumor to decrease the adhesion formation risk and facilitate tumor removal during second operation if performed after more days. The cohort was composed by a consecutive series of 11 patients underwent to surgery for spine and pelvic tumor where Gore-Tex mesh spacer was placed. In this study, efficiency and tolerability of Gore-Tex mesh were evaluated. No case of adhesion between Gore-Tex mesh and surrounding structures is reported, no case of migration or complications occurred. Gore-Tex mesh use can be considered a useful and safe procedure to decrease the risk of adhesion formation between tumor and surrounding tissue so that to allow the tumor removal easier.
2010
01 Pubblicazione su rivista::01a Articolo in rivista
The Gore-Tex biomaterial mesh as temporary divisor in two times surgery for spinal and pelvic tumors / Zoccali, C; Prencipe, U; Favale, L; Di Filippo, F.. - In: MUSCULOSKELETAL SURGERY. - ISSN 2035-5106. - 94:1(2010), pp. 21-24.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1671970
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact